| Price | USD 230-280 |
| MOQ | 1 |
| Delivery Time | Within 3 days |
| Brand | RAINBOW |
| Place of Origin | Hunan,China |
| Certification | ISO13485,FSC |
| Model Number | RBH-700 |
| Packaging Details | carton box |
| Payment Terms | L/C, T/T, Western Union, MoneyGram |
| Supply Ability | 1 |
| Brand Name | RAINBOW | Payment Terms | L/C, T/T, Western Union, MoneyGram |
| Place of Origin | Hunan,China | Price | USD 230-280 |
| Delivery Time | Within 3 days | brand name | RAINBOW |
| Minimum Order Quantity | 1 | Packaging Details | carton box |
| weight | 1.20kg | Model Number | RBH-700 |
| Supply Ability | 1 | Certification | ISO13485,FSC |
| Main features: |
| Reliable and Safe: |
| 1, Additional set of bubble alarm design(double bubble alarm) ensure more secure infusion; |
| 2, Advanced safety design able to stop infusion and alarm even if the CPU damage,the medical staff can ues it safely; |
| 3.multipurpose: |
| It can be transfused, transfused blood and transported nutrient solution. |
| Pumping way: |
| Semi-squeeze finger-type peristaltic pump |
| IV-sets: |
| Special or quality PVC/TPE infusion sets with an external diameter of 3.4mm~4.5mm |
| User options: |
| No |
| Infusion modes: |
| 4 infusion modes: |
| 1, Flow-rate: ml/h; |
| 2, Time-amount: ml/h; |
| 3, Drop-rate: d/min; |
| 4, Body-weight: mg/kg/h |
| Parameter range |
| 1, Flow-rate: 1.0~1200.0 ml/h, 0.1ml/h step; |
| 2, Time: 1s~99h59m59s, 1s step; |
| 3, Drop-rate: 1~333 d/min, 1 d/min step; |
| 4, Dose: 0.1~999.9 mg, 0.1mg step; |
| 5, mg/kg/h: 0.001~999.999 mg/kg/h, 0.001 mg/kg/h step; |
| 6, Body-weight: 1~300 kg, 1kg step; |
| 7, KVO rate: 1.0~5.0 ml/h, 0.1 ml/h step; |
| 8, Bolus rate: 50.0~800.0 ml/h, 0.1 ml/h step; |
| 9, Bolus volume: 0.1~99.9 ml/h, 0.1ml step |
| Precision |
| Better than ±5% (using a calibrated or a special IV-set) |
| Alarm |
| 1, Air in tube, 5 grades of sensitivity (double bubble alarm); |
| 2, Bubble sensor fault; |
| 3.1, Upper-end occlusion, -20~ -60 kPa,8 grades of sensitivity; |
| 3.2, Upper-end base-pressure fault; |
| 4.1, Lower-end occlusion, 20~ 140 kPa,8 grades of sensitivity; |
| 4.2, Lower-end base-pressure fault; |
| 5.1, Pump rotation fault; |
| 5.2, Inverse-infusion; |
| 6, Abnormal door-opening; |
| 7, Low battery power, battery fault; |
| 8, Overtime pause; |
| 9, Completed infusion; |
| 10, AC power fault; |
| 11, MCU fault, and stop infusion; |
| 12, Battery temperature is too high. |
| Data function: |
| 1, Memory of calibration: Records the calibration data of tube automatically for application; |
| 2, Memory of parameter: Records the latest infusion parameter for next operation; |
| 3, Historical records: records latest 1000 infusion events. |
| (what/when/why,flow-rate, etc.) |
| Safety classification: |
| Class I; Internal power supply, CF type, IPX4 equipment |
| Power supply: |
| AC 100~240V, 50/60Hz, Built-in rechargeable Li-battery |
| Power consumption:20VA |
| Working time of battery: 7h@25ml/h |
| Weight and size: |
| 130mm(w)*206mm(h)*118mm(t); about 1.6kg |
| Optional accessories: |
| 1, Warmer; |
| 2, Wireless communicating module. |
| Chinese Certificate: |
| yes |