Price | USD 250-280 |
MOQ | 1 |
Delivery Time | Within 3 days |
Brand | RAINBOW |
Place of Origin | Hunan,China |
Certification | ISO13485,FSC |
Model Number | RBH-700 |
Packaging Details | Carton box |
Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 10000units/year |
product name | infusion pump | Place of Origin | Hunan,China |
Packaging Details | Carton box | weight | 1.20kg |
Model Number | RBH-700 | Supply Ability | 10000units/year |
Certification | ISO13485,FSC | MOQ | 1 |
Brand Name | RAINBOW | Payment Terms | L/C, T/T, Western Union, MoneyGram |
Price | USD 250-280 | Delivery Time | Within 3 days |
brand name | RAINBOW | OEM | YES |
Minimum Order Quantity | 1 |
Technology Parameters of Infusion Pump
Main features:
Reliable
and
Safe:
1,
Additional
set
of
bubble
alarm
design(double
bubble
alarm)
ensure
more
secure
infusion;
2,
Advanced
safety
design
able
to
stop
infusion
and
alarm
even
if
the
CPU
damage,the
medical
staff
can
ues
it
safely;
multipurpose:
It
can
be
transfused,
transfused
blood
and
transported
nutrient
solution.
Pumping way:
Semi-squeeze finger-type peristaltic pump
IV-sets:
Special or quality PVC/TPE infusion sets with an external diameter of 3.4mm~4.5mm
User options:
no
Infusion modes: |
1.
infusion
modes: 2, Flow-rate: ml/h; 3, Time-amount: ml/h; 4, Drop-rate: d/min; 5, Body-weight: mg/kg/h |
Parameter range: |
1,
Flow-rate:
1.0~1200.0
ml/h,
0.1ml/h
step; 2, Time: 1s~99h59m59s, 1s step; 3, Drop-rate: 1~333 d/min, 1 d/min step; 4, Dose: 0.1~999.9 mg, 0.1mg step; 5, mg/kg/h: 0.001~999.999 mg/kg/h, 0.001 mg/kg/h step; 6, Body-weight: 1~300 kg, 1kg step; 7, KVO rate: 1.0~5.0 ml/h, 0.1 ml/h step; 8, Bolus rate: 50.0~800.0 ml/h, 0.1 ml/h step; 9, Bolus volume: 0.1~99.9 ml/h, 0.1ml step |
Precision:
Better than ±5% (using a calibrated or a special IV-set)
Data function: |
1,
Memory
of
calibration:
Records
the
calibration
data
of
tube
automatically
for
application; 2, Memory of parameter: Records the latest infusion parameter for next operation; 3, Historical records: records latest 1000 infusion events. (what/when/why,flow-rate, etc.) |
Safety classification:
Class I; Internal power supply, CF type, IPX4 equipment
Power supply:
AC 100~240V, 50/60Hz, Built-in rechargeable Li-battery
Power consumption:20VA
Working time of battery: 7h@25ml/h
1, Air in tube, 5 grades of sensitivity (double bubble alarm); |
2, Bubble sensor fault; |
3.1, Upper-end occlusion, -20~ -60 kPa,8 grades of sensitivity; |
3.2, Upper-end base-pressure fault; |
4.1, Lower-end occlusion, 20~ 140 kPa,8 grades of sensitivity; |
4.2, Lower-end base-pressure fault; |
5.1, Pump rotation fault; |
5.2, Inverse-infusion; |
6, Abnormal door-opening; |
7, Low battery power, battery fault; |
8, Overtime pause; |
9, Completed infusion; |
10, AC power fault; |
11, MCU fault, and stop infusion; |
12, Battery temperature is too high. |