                                        | Price | USD$49-69 | 
| MOQ | 1pc | 
| Delivery Time | 3-7 working days | 
| Brand | WelandSignal | 
| Place of Origin | SHAANXI, CHINA | 
| Certification | ROHS,CE | 
| Model Number | OL32 | 
| Packaging Details | Each has one small carton | 
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability | 20000pcs/month | 
| Light source | super bright medium intensity LED | Place of Origin | SHAANXI, CHINA | 
| Warranty | 5 years | Waterproof | IP67 | 
| Packaging Details | Each has one small carton | Color | Red, Green, Yellow, Blue, White | 
| FAA | Compliant with Obstruction Light Type L-810 as per FAA Advisory Circular AC 150/5345-43G 09/26/12 (Red). | Material | Polycarbonate, Shock-resistance, anti-UV, Salt and dust self-protection | 
| Peak intensity | 10cd,32.5cd,300cd | ICAO | Meets ICAO requirements for Low-Intensity Obstacle Lights Type A and Type B, according to ICAO Annex 14, Volume 1, 5th Edition, July 2009 and 6th Edition, July 2013 (Red). | 
| Model Number | OL32 | Supply Ability | 20000pcs/month | 
| Certification | ROHS,CE | Brand Name | WelandSignal | 
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Price | USD$49-69 | 
| Delivery Time | 3-7 working days | Minimum Order Quantity | 1pc | 
| Voltage | 110-220VAC,12VDC,4VDC,48VDC | Working Mode | Flashing, steady on | 
| GPS Synchronization | Optional GPS enables two or more lights to flash in unison | Application | tower, chimney ,tall buildings, bridge aviation obstruction lighting area | 
  The
  OL32/OL10
  Tall
  Buildings
  Led
  Aircraft
  Warning
  Lights
  is
  a
  stable
  burning
  low
  intensity
  LED
  obstruction
  light
  designed
  to
  meet
  ICAO
  LIOL
  Type
  A
  and
  B
  requirements.
  The
  model
  can
  be
  used
  to
  mark
  obstacles
  up
  to
  45
  meters
  above
  the
  ground,
  such
  as
  telecommunications
  towers,
  wind
  turbines,
  buildings,
  and
  other
  tall
  structures.
  The
  OL32/OL10
  Tall
  Buildings
  Led
  Aircraft
  Warning
  Lights provide
  an
  ultra-bright,
  energy-efficient
  and
  cost-effective
  lighting
  solution.
  Adjustable
  intensity
  settings
  allow
  users
  to
  easily
  switch
  between
  10cd
  (Type
  A)
  and
  32cd
  (Type
  B).
  The
  luminaire
  is
  available
  in
  two
  configurations,
  Universal
  DC
  (12-48VDC)
  or
  Universal
  AC
  (110-240VAC).
  Advanced
  optics
  use
  a
  single
  LED
  for
  lowest
  power
  consumption.
  Corrosion-resistant
  polycarbonate
  lenses
  are
  specifically
  designed
  for
  use
  with
  LEDs
  to
  maximize
  light
  intensity
  and
  uniformity.
  The
  luminaire
  contains
  internal
  diagnostic
  checks
  and
  alarm
  contacts
  for
  remote
  monitoring.
  The
  alarm
  relay
  is
  energized
  during
  normal
  operation
  and
  will
  release
  as
  long
  as
  the
  LED
  is
  not
  lit.
  The
  unit
  is
  available
  in
  3/4
  or
  1"
  thread
  styles
  -
  making
  retrofitting
  of
  existing
  units
  simple.
  Obstruction
  lights
  can
  also
  be
  used
  to
  combine
  visual
  and
  infrared
  (IR)
  for
  pilots
  using
  night
  vision
  to
  see.
  
  
  SPECIFICATIONS
   
| 
 
          OL32/OL10
          Tall
          Buildings
          Led
          Aircraft
          Warning
          Lights | |||
| Mechanical Specifications | Electronic Specifications | ||
| 
 Peak Intensity 
 | 10cd,32.5cd,300cd | Structure | Integrated Design | 
| 
 Working Model 
 | Flahing/Steady On | Lens Material | Polycarbonate | 
| 
 Protect Level 
 | IP67 | Input Voltage | 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC | 
| 
 LED 
 | Super-bright medium intensty Leds | Function Optional | Synchronization | 
| 
 Temperature 
 | -45℃~70℃ | Mounting | 4 bolts M6 | 
| 
 Automatic Light Control (ALC) 
 | Turn on at night and off at daytime automatically | OEM Service | Color:
        Red,
        Green,
        Yellow,
        Blue,
        White Flashing frequency | 
  
   
  
  
  KEY
  FEATURES
  •
  Cost-effective,
  energy-efficient
  obstacle
  lighting
  solutions.
  •
  Universal
  DC
  available:
  12–48VDC
  acceptable.
  •
  Universal
  AC
  available:
  110-240VAC
  acceptable.
  •
  User
  adjustable
  intensity
  to
  switch
  between
  ICAO
  LIOL
  Type
  A
  (10cd)
  and
  LIOL
  Type
  B
  (32cd).
  •
  Alarm
  contacts
  for
  remote
  monitoring.
  •
  Light
  sensor
  for
  day/night
  operation.
  •
  LED
  technology
  reduces
  maintenance
  time
  and
  costs.
  •
  Easy
  retrofit
  with
  existing
  installations.
  •
  Available
  in
  optional
  solar
  configuration.
   
   
  
  
  SIZE
  (mm)
   
  
  
  
  Dual
  Lighting
  Model
  OL10/32
  110V/220V
  Low
  Intensity
  Dual
  LED
  Obstruction
  Light
  is
  designed
  to
  survive
  and
  perform
  in
  airway
  fixed
  obstacle
  marking
  applications
  with
  a
  waterproof,
  vibration
  proof
  and
  corrosion
  resistance
  casing.
  It
  comply
  with
  ICAO
  regulation,
  low
  intensity,
  type
  A/type
  B.
  Working
  mode
  is
  steady
  burning.
  OL-D10/32
  Series
  Double
  Light
  Double
  light
  is
  integrated
  by
  2
  single
  lights.
  For
  making
  sure
  there
  is
  always
  a
  light
  working
  at
  the
  top
  of
  the
  tower.
  Two
  optional
  working
  patterns
  can
  meet
  different
  area’s
  customers.
  “Service+Standby”:
  Only
  “service
  light”
  is
  working
  normally.
  It
  will
  auto-transfer
  to
  “standby
  light”
  in
  case
  of
  ”service
  light”
  failure
  “Service+Service”:
  Two
  single
  lights
  work
  simultaneously.
  Either
  failure
  will
  not
  affect
  the
  other
  normal
  working.
  
   
  
   
   
  
  Installation
  
   
  
  
  
  
  STANDARS
  
  
  
  
  High-rise
  building
  aviation
  obstacle
  light
  configuration
  scheme
  The
  obstacle
  lights
  set
  up
  by
  high-rise
  buildings
  and
  building
  complexes
  should
  be
  able
  to
  see
  the
  outline
  of
  the
  object
  from
  all
  directions,
  and
  the
  horizontal
  direction
  can
  also
  refer
  to
  the
  barrier
  lights
  set
  at
  a
  distance
  of
  about
  45
  meters,
  and
  the
  general
  building
  should
  install
  obstacle
  lights
  at
  the
  top
  of
  it,
  and
  the
  installation
  height
  H
  is
  calculated
  from
  the
  horizontal
  ground.
  Reference
  Standards:
  CAAC,
  ICAO,
  FAA
  MH/T6012-2015,
  MH5001-2013
  