Price | $300 to $2000 |
MOQ | 1 |
Delivery Time | 7 work days |
Brand | NUOYINGJIAYE |
Place of Origin | China |
Certification | Explosion-proof certificate |
Model Number | NYLD-G |
Packaging Details | Export standard packing |
Payment Terms | T/T |
Supply Ability | 300 pcs/ pre month |
Place of Origin | China | Packaging Details | Export standard packing |
Accuracy grade | ±1.5%R,±1.%R | Output signal | Pulse frequency signal output: Low level is below 0.8V,high level is 8V Two-wire, three-wire 4-20mA current output |
Power supply | 24VDC, 220VAC (optional) | Transmission distance | ≤1000m |
Model Number | NYLD-G | Supply Ability | 300 pcs/ pre month |
Certification | Explosion-proof certificate | Ambient humidity | 5%~90% |
Brand Name | NUOYINGJIAYE | Payment Terms | T/T |
Range ratio | 1:10,1:20 | Price | $300 to $2000 |
Delivery Time | 7 work days | Minimum Order Quantity | 1 |
Measured medium temperature | -30~80℃ | Communication output | Rs485 communication MODBUS protocol, HART communication interface |
NYLD-G Gas Eletromagnetic Flowmeter
The NYLD-G gas turbine flowmeter is a new generation of high precision, high reliability gas precision measuring meter integrating temperature, pressure, flow sensor and intelligent flow totalizer developed by the advanced technology of flow meter at home and abroad, optimized by theories of gas mechanics, fluid mechanics and electromagnetics, which has excellent low pressure and high pressure metering performance.
It
has
a
variety
of
signal
output
modes
and
low
sensitivity
to
fluid
disturbances,
and
is
widely
used
in
the
measurement
of
natural
gas,
coal
gas,
liquefied
gas,
light
hydrocarbon
gas.
This
type
of
turbine
flowmeter
is
an
explosion-proof
product
with
an
explosion-proof
rating:
ExdIICT6
NYLD-G Gas Eletromagnetic Flowmeter Technical Parameters
Basic Parameters
Metercaliber(mm) andconnection mode |
DN50, DN80,DN100,DN150,DN200,DN250, DN300mm caliber with flange connection DN25,DN40, DN65,DN125mm can be customized |
Accuracy grade | ±1.5%R,±1.%R |
Range ratio | 1:10,1:20 |
Meter materia | Body:cast aluminum or 304 stainless steel; impeller:high quality aluminum alloy; display: cast aluminum |
Measured medium temperature | -30 ° C ~ +80 ° C, |
Ambient condition | Temperature: -20 ° C ~ +60 ° C, relative humidity 5%~90%. atmospheric pressure |
Power supply |
External power supply:24VDC Internal power supply:3.6Vlithium battery |
Output signal |
Pulse frequency signal output: low level is below 0.8V,high level is 8V Two-wire, three-wire 4-20mA current output |
Transmission distance |
≤1000m |
Signal wire interface |
Internal thread M20×1.5 |
Protection grade | IP65 |
Explosion-proof grade |
Exd II CT6 |
Technical parameters
Model specification Range |
Nominal diameter DN |
Flow range m3/h |
Nominal pressure Mpa |
Accuracy |
Pressure loss kPa at Qmax |
NYLD-G-25 A | 25 | 2.5 ~25 |
1.6 2.5 4.0 |
1. 5grade (Qmin ~qtx ±3% qtx~Qmax ±1.5%) 1.0grade (Qmin ~qtx ±2% qtx~Qmax ±1.0%) |
0.5 0.8 |
NYLD-G-40 A | 40 | 5 ~ 50 | |||
NYLD-G-50 A B |
50 |
6~65 10~100 |
|||
NYLD-G-65 A | 65 | 15~200 |
0.8 1.2 2.2 |
||
NYLD-G -80 A B |
80 |
13~250 20~400 |
|||
NYLD-G -100 A B NYLD-G -125 A |
100
125 |
20 ~400 32~650 25~700 |
0.3 0.7 1.9 |
||
NYLD-G -150 A B C |
150 |
32 ~650 50~1000 80~1600 |
1.6 2.5 |
0.6 1.0 1.7 |
|
NYLD-G -200 A B C |
200 |
50 ~ 1000 80~1600 130~2500 |
0.3 0.6 1.5 |
||
NYLD-G -250 A B C |
250 |
80 ~ 1600 130~2500 200~4000 |
0.4 0.6 2.0 |
||
NYLD-G -300 A B C |
300 |
130 ~2500 200~4000 320~6500 |
0.4 1.0 2.4 |
Note: the pressure loss at the maximum flow rate (Q) is the value measured with dry air (density is about 1.2 kg/m) under normal pressure, qt = 0.2Qmax.
NYLD-G Gas Eletromagnetic Flowmeter Operating Principle
When the fluid passes through the flowmeter, it is rectified and accelerated by the action of the guide vane (or rectifier). Since the impeller is at an angle to the fluid flow direction, at this time,the turbine generates a rotational moment. After overcoming the friction torque and the fluid resistance torque, the turbine starts to rotate. In a certain flow range, the angular velocity of the turbine rotation is proportional to the volume flow rate of the fluid. According to the principle of electromagnetic induction, a magnetic sensitive sensor is used to induce a pulse signal proportional to the volume flow of the fluid from the synchronously rotating communicating plate. This signal is sent to the volume corrector and is processed together with signals such as temperature and pressure, and displayed on the LCD screen. Its structure principle is shown in Figure 1..
4.2Volume Corrector Working Principle
The volume corrector consists of temperature, pressure detection analog channel, flow detection digital channel, micro processing unit, liquid crystal drive circuit and other auxiliary circuits, and it is equipped with an external signal interface.After converting and processing the multi-channel signals sent from each sensor, the signals is brought into the formula for operation according to the gas equation to realize the local display and remote transmission of various signals.
The gas equation can be written as
Where:
Vo — the volume unde3r the standard condition (m3);
V — the volume under the3 working condition (m3);
P=Pa+Pg — the absolute pressure (kPa) at the flowmeter pressure detection point;
Pa — local atmospheric pressure (kPa);
Pg—the meter pressure (kPa) of the flowmeter pressure detection point;
P0 — the standard atmospheric pressure (101.325kPa)
T0 — the absolute temperature under the standard condition (293.15K, which can be 273.15K according to user requirements);
T — the absolute temperature of the measured medium (27315+t)K;
t — the temperature of the measured medium (°C);
Fz—Gas compression coefficient
Zn — the gas compression coefficient under standard sate
Zg — the gas compression coefficient under working condition;
NYLD-G Gas Eletromagnetic Flowmeter Design Features
■
High
precision,
good
repeatability
and
wide
range
ratio,up
to
1:20
(or
wider);
■ Use integrated type new rectifier, the requirements for the front and rear straight pipe sections are lower (front ≧5DN, rear ≧3DN);
■ Use a carefully designed dust-proof structure to ensure the reliability of long-term bearing operation;
■ Designed with a unique fueling system to ensure reliable fueling, easy maintenance and beautiful appearance;
■ Thetechnical indicators meet the requirements of I509951-1993,the length of the body is 3DN, and the whole machine has reachedthe international advanced level;
■ Thevolume corrector of the flowmeter can be rotated freely by about 350 degrees, which can be easily read in various installation modes.
■ Low speed, high life, low pressure loss, high precision;
■ It integrates high-precision temperature, pressure, flow sensor and volume corrector, which can detect the temperature, pressure and flow of the measured gas, and automatically track and compensate the flow and correct the compression coefficient. The meter has real-time database and communicatesvia RS485 interface and meter reading network to facilitate centralized data collection and real-time management;
■ Use high-performance microprocessor and modern digital filtering technology, with powerful software functions and superior performance;
■
Use
floating
point
calculation
and
automatic
correction
of
five-segment
meter
coefficient,
and
has
fault;
self-diagnosis
and
alarm
function;
■
Use
micro-power
high-tech,
with
internal
and
external
power
supply,
and
low
power
consumption;
■
Local
display
flow
value
with
multiple
signal
output
functions;
■
Use
a
high-contrast
three-line
LCD
display,
it
can
display
standard
cumulative
flow,
standard
volume
flow,
working
volume
flow,
medium
temperature,
pressure
value
and
battery
capacity
percentage
with
Chinese
prompt;
■
With
real-time
data
storage
function,
it
can
prevent
data
loss
when
battery
is
replaced
or
suddenly
power
down
.
In
the
power-off
condition,
internal
parameters
can
be
permanently
saved.
■
With
explosion-proof
function,
the
explosion-proof
mark
is
ExdIIC6.