Price | $1300-$1800/PC |
MOQ | 1 |
Delivery Time | 14 work days |
Brand | KOSO |
Place of Origin | Japan |
Certification | CCC CE ISO |
Model Number | EP1000 |
Packaging Details | Strong carton Packing with export standard. If each model more than 300PCS can make colored strong carton |
Payment Terms | L/C, T/T, Western Union, D/P |
Supply Ability | 1000Piece/Pieces per Month |
Input impedance | 500Ω at 20mA (Input voltage less than 10V) | Place of Origin | Japan |
Packaging Details | Strong carton Packing with export standard. If each model more than 300PCS can make colored strong carton | Characteristic | Linear (Desired characteristic settable) |
Air Supply | 140 to 700kPa | Power supply | 2-Wire type |
Model Number | EP1000 | For single acting actuator | Repeatability : 0.2% of FS. |
Supply Ability | 1000Piece/Pieces per Month | Certification | CCC CE ISO |
Brand Name | KOSO | Payment Terms | L/C, T/T, Western Union, D/P |
Price | $1300-$1800/PC | Delivery Time | 14 work days |
Ambient temperature | Explosion type : -20 to 60° | Minimum Order Quantity | 1 |
This is an intelligent electropneumatic positioner that conforms to field equipment communication standard HART, which is a world standard.
It permits easy and positive digital adjustment of positioner response characteristics and zero and span from a host equipment mounting DDL or from an HHC (Hand Held Communicator). Furthermore, with 3-key calibration executed by a pushbutton built in the positioner, it is possible to set principal items by unit positioner, without need for HHC or the like.
It can be mounted to an actuator of any of single action type, double action type, rotary type and linear type, and it operates with a 4-20mA instrumentation signal and compressed air. Therefore, it is a positioner of broad universality, and it is capable of transmitting self-diagnosis information and others besides valve opening and open/close limit signals to a host equipment that conforms to HART.
KOSO is now developing FF dealing equipment, which digitalizes up to control signals and conforms to Fieldbus Foundation Standards.
Series | EP1000 | |
---|---|---|
Applicable Actuators | Single and double acting actuators | |
Input Signal | 4 to 20mA DC (adjustable to 1/4 split range) | |
Power supply | 2-Wire type | |
Input impedance | 500Ω at 20mA (Input voltage less than 10V) | |
Characteristic | Linear (Desired characteristic settable) | |
Pilot valve |
Non-bleeding
type Single acting and double acting types are available |
|
Air supply | 140 to 700kPa | |
Air consumption |
Output
air
pressure
50% 5Nl/min at 140kPa air supply 15Nl/min at 400kPa air supply |
|
Max. capacity |
Capacity
when
output
is
atmospheric
venting 175Nl/min at 140kPa air supply 400Nl/min at 400kPa air supply |
|
Performance |
For
single
acting
actuator Linearity : +/-1.0% of FS. Hysteresis : 0.5% of FS. Response level : 0.1% of FS. Repeatability : 0.2% of FS. |
For
double
acting
actuator Linearity : +/-1.5% of FS. Hysteresis : 0.8% of FS. Response level : 0.2% of FS. Repeatability : 0.3% of FS. |
The above represents the performance of the positioner on an actuator without a valve. For the performance of the complete unit with a valve and an actuator, see KOSO STANDARD SPECIFICATION. | ||
Calibration |
1
button
calibration Calibration by positioner alone. Own program with Note PC or Disktop PC |
|
Self diagnosis items |
Air
supply
check/Eath
unit's
function
check/Over
load
check Fail position for breakdown selectable |
|
Air connection | Rc 1/4 | |
wiring connection | G 1/2 | |
Ambient temperature | Standard type : -20 to 80°, Explosion type : -20 to 60° | |
Ambient humidity range | 10 to 90% RH | |
Enclosure | Weather proof type (IP65), Explosion proof type (ExdCT6) | |
Standard anicillary | Auto-Manual change | |
Housing material | Aluminum alloy | |
Coating | Epoxy resin group paint | |
Coating colors | Body : Dark green, Cover : Light gray | |
Apporox. Weight | 2.6kg | |
Optional specifications | Available upon request | |
Position transmitter |
4
to
20mA
2-Wire
type Power source required in addition to input signal. |
|
Limit switches |
Open/Shut Open collector type |
|
Self diagnosis indication |
diagnosis
result
on
LED Separate power supply required |
|
wiring connection | 1/2 NPT | |
Air connection | 1/4 NPT |