8"
color
TFT
LCD
screen,
resolution
800*600
●
Waterproof
design,
resistance
to
dropping
(1
meter)
●
Support
external
13-20V
DC
power,
continuously
working
for
5.5
hours
above
on
battery
backup,
full
charge
with
2.5
hours,
suitable
for
Ambulance,
Emergency
Transport
●
Display
mode:
Big
font,
trends
review,
7
leads
ECG
waveform
on
same
screen,
and
etc
●
15
kinds
of
arrhythmia
analysis,
15
kinds
of
drug
concentration
analysis
●
Anti-electro
surgical
unit
(300W),
anti-defibrillation
(360J),
suitable
for
Operating
Room,
General
Ward
●
Digital
SpO2
technology,
excellent
anti-
interference
performance,
low
perfusion
(0.1%)
●
USB
data
output
with
software
to
view
data
on
computer
Technical
parameters
ECG
|
Lead
|
Standard
3/5
lead
|
Lead
Mode
|
5
Leads
(RA,
LA,
LL,
RL,V)
|
Lead
Selection
|
I,
II,
III,
avR,
avL,
avF,
V
|
Lead
Mode
|
3
Leads
(RA,
LA,
LL)
|
Lead
Selection
|
I,
II,
III,
|
Gain
|
2.5mm/mV,
5.0mm/mV,
10mm/mV,
20mm/mV
|
HR
and
Alarm
Range
|
Adult:
15
~
300
bpm
Ped/Neo:
15
~
350
bpm
|
Accuracy
|
±1%
or±1bpm,
which
is
greater
|
Resolution
|
1
bpm
|
Sensitivity
|
>
200
(uVp-p)
|
Differential
Input
Impedance
|
>
5
MΩ
|
Bandwidth
|
Surgery
1
~
20
Hz
Monitor
0.5
~
40
Hz
Diagnostic
0.05
~130
Hz
|
CMRR:
|
Monitor
>
100
dB
Operation
>
100
dB
Diagnosis
>
90
dB
|
Electrode
Offset
Potential:
|
±300mV
|
Range:
|
±2
mV
~
±700
mV
|
Width:
|
0.1
ms
~
2
ms
|
Rise
time:
|
10
us
~
100
us
|
ST
Segment
Monitoring
Range:
|
Measurement
Range:
-2.0
~
+2.0
mV
Measurement
Accuracy:
-0.8
~
+0.8
mV
Measurement
Error:
±0.02
mV
or
±10%
|
SPO2
|
Measure
range
|
0-100%
|
Resolution
|
1%
|
Accuracy
|
±2%
(70-100%)
|
Pulse
Rate
|
20-300
BPM
|
Resolution
|
1BPM
|
Accuracy
|
±3BPM
|
NIBP
|
Work
Mode
|
Manual,Automatic,
STAT
|
Method:
|
Oscillometric
|
Measuring
Interval
in
Auto
Mode:
|
1,
2,
3,
4,
5,
10,
15,
30,
60,
90,120,
180,
240,480
(Min)
|
Measuring
Period
in
STAT
Mode:
|
5
Min
|
Pulse
Rate
Range:
|
40
~
240
bpm
|
Measuring
and
Alarm
Range:
|
Adult
|
SYS
40
~
270
mmHg
DIA
10
~
215
mmHg
MEAN
20
~
235
mmHg
|
Pediatric
|
SYS
40
~
200
mmHg
DIA
10
~
150
mmHg
MEAN
20
~
165
mmHg
|
Neonatal
|
SYS
40
~
135
mmHg
DIA
10
~
100
mmHg
MEAN
20
~
110
mmHg
|
Static
Pressure
Range:
|
0
~
300
mmHg
|
Static
Pressure
Accuracy:
|
±3mmHg
|
Accuracy:
|
Maximum
Average
Error
±5mmHg
Maximum
Standard
Deviation
±8mmHg
|
Over
pressure
Protection:
|
Adult
Mode:
300
mmHg
Pediatric
Mode:
240
mmHg
Neonatal
Mode:
150
mmHg
|
RESP
|
Method:
|
Impedance
Between
RA-LL
or
RA-LA
|
Measuring
Impedance
Range:
|
0.3~3
Ω
|
Base
line
Impedance
Range:
|
200~4
KΩ
|
Bandwidth:
|
0.1~2.5Hz
|
Measuring
and
Alarm
Range:
|
Adult:
2
~
120
BrPM
Neo/Ped:
2
~
150
BrPM
Resolution:
1
BrPM
Accuracy:
±2
BrPM
Apnea
Alarm:
10
~
40
S
|
TEMP
|
Applicable
Temperature
Sensor:
|
YSI,
CYF
|
Channel:
|
1
|
Measure
range
|
0-50ºC
|
Resolution
|
±0.1
℃
|
Accuracy
|
±0.1
℃
(Do
not
including
sensor
error)
|
Detail