Price | Negotiable |
MOQ | 1 unit |
Delivery Time | Within 3 days |
Brand | Rainbow |
Place of Origin | China |
Certification | ISO13485 |
Model Number | RBH-800 |
Packaging Details | Foam+Carton box Carton box dimension: 29*27*21.6cm Gross weight: 2.2kg |
Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 30000units/year |
Place of Origin | China | Warranty | 1 year |
Packaging Details | Foam+Carton box Carton box dimension: 29*27*21.6cm Gross weight: 2.2kg | Product Name | Syringe pump |
KVO speed range | 2.5ml/h | Dimension | 248*151.5*97mm |
Model Number | RBH-800 | Battery working time | No less than 8 hour |
Supply Ability | 30000units/year | After-sale Service | Online technical support |
Certification | ISO13485 | MOQ | 1 set |
Brand Name | Rainbow | Payment Terms | L/C, T/T, Western Union, MoneyGram |
Infusion Mode | speed infusion,speed time infusion,speed volume infusion | Price | Negotiable |
Delivery Time | Within 3 days | Minimum Order Quantity | 1 unit |
Display | 4.3 inch LCD |
Product
Description
This
product
doesnot
provide
an
infusion
set,
It
has
a
safety
design
that
avoids
misoperation
during
infusion
and
doesnot
cut off
the
power
immediately
after
pressing
the
power
button.
It
has
a
safe
design
to
prevent
air
bubbles
in
the
infusion
from
entering
the
patient's
blood
vessel.
The
device
can
use
two
types
of
power
sources:
AC
power
and
built-in
battery
power.
①:Alarm
indicator
②:Start/stop
injection
button
③:Mute
button
④:Quick
button
⑤:Power
button
⑥:Syringe
pump
pushrod
⑦:Display
screen
Features
Alarm
information
and
processing
method
Alarm items and alarm display | reasons | Treatment suggestion |
The
liquid
will
be
exhaused |
Preset amount or set time remaining 5% | After the infusion solution is used up, if you want to continue the infusion, you should replace the infusion bottle or infusion bag; if the infusion solution is not used up, check whether the installation position of the drip rate sensor is correct or whether it is abnormally inclined. |
Infusion
completed |
The infusion has reached the set time or volume value | Press the mute button to eliminate the prompt |
Blocked
tubing |
The infusion push rod is blocked and the pressure reaches the alarm value | Check if there is any interference in the push rod, reinstall the syringe without interference or increase the blocking pressure level. If the blocking alarm occurs again, immediately stop using the system and contact the distributor/manufacture where you purchased the product. |
Battery
is
low |
When the battery power is 20% remaining | Check whether the power supply used is properly connected to the system.(this alarm can be cleared by long pressing the mute button. and this alarm will not be reported in the future;or access to the AC to clear the alarm and the subsequent AC power faliure will continue to alarm) |
Dead battery |
When the battery power is less than 5% | Immediately connect to AC power and the alarm is eliminated.(you cannot slience the alarm sound by pressing the "mute button") |
Syringe
not
installed |
During the infusion, the syringe was not detected | Check whether the currently set syringe manufacturer selection is the manufacturer required by 6.5.4,If you have redefined the syringe type yourself, please switch to the set syringe manufaturer number. |