Product Specification

Insulation MgO Place of Origin NINGBO CHINA
Warranty 1 Year Theory Temperature Sensor
Thermocouple Type K/N/E/J/T/S/R/B Packaging Details 70*70*8cm Carton
Model Number LK-K Supply Ability 1,000,000M/year
Certification ISO9001, IATF16949, CE Brand Name LEADKIN
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Function temperature test
Accuracy Class I、II、III Price negotiation
Delivery Time 2-7 working days Minimum Order Quantity 50M
Temperature Range 200℃-1000℃ Cable Length 1-5m or Customized
Package Carton. Pallet Outside Dia 0.5-12.7mm
Core 2,3,4,6

Product Description

Type S Thermocouple Cable - High Temperature Resistant Wire
Premium thermocouple cable designed for kilns, ovens, and high-temperature industrial equipment applications.
Product Specifications
Type: K/N/E/J/T/S/R/B
Origin: Zhejiang, China
Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
Core Number: 2, 3, 4, 6
Lead Material: Ni, Cu
Insulator: 99.6% high purity MgO
Certifications: ISO9001, IATF16949, CE
Application: Connecting thermocouples with instrument machines
Sheath Material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
Sheath Diameter: φ3.0, φ4.0, φ6.0, φ8.0
Sheath Wire Specifications by Type
Product Name Code Type Sheath Material Outside Dia. (mm) Temperature (°C)
NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
SS310 Inconel6000.5-1.0500
1.5-3.2800
4.0-6.4900
8.0-12.71000
NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
SS310 Inconel6000.5-1.0500
1.5-3.2800
4.0-6.4900
8.0-12.71000
NiCr-KonstantanEKESS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
Fe-KonstantanJKJSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
Cu-KonstantanTKTSS304 SS3160.5-1.0400
1.5-3.2600
4.0-8.0800
RhPt10-PhSKSInconel6006.0-12.71100
Note: Different temperature measuring media and service conditions impact service life and temperature range. Table data is for reference only.
Accuracy Specifications
Type Class I Accuracy Class I Temp. Range Class II Accuracy Class II Temp. Range
K±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-1000℃±0.75%375℃-1000℃
N±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-1000℃±0.75%375℃-1000℃
E±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-800℃±0.75%375℃-800℃
J±1.5℃-40~375℃±2.5℃-40~375℃
±0.4%375℃-800℃±0.75%375℃-800℃
T±0.5℃-40~125℃±1.0℃-40~125℃
±0.4%125℃-350℃±0.75%125℃-350℃
S±1.0℃0-1100℃±1.5℃0-1100℃
Product Features
  • Inorganic mineral insulated cable construction with pure nickel/copper wire, mineral insulation, and metal sleeve
  • Designed for high-temperature environments (200℃~1000℃)
  • Suitable for corrosive environments, flames, metal solutions, and liquid immersion
  • Small outer diameter with fast thermal response time
  • Flexible design allows bending and installation in narrow, curved pipelines
  • Long service life with excellent airtightness and high pressure resistance
  • Wide temperature measurement range: -200°C to 1300°C (optional)
  • Available in K, N, E, J, T, S, R, B types, in pairs or duplicate configurations
  • Outer sheath diameter range: Φ0.5 to Φ12.7 with multiple material options
What is a Thermocouple?
A thermocouple is a transducer that converts thermal energy into electrical energy by joining wires of dissimilar metals to create a junction. Temperature changes at this junction generate measurable voltage for temperature determination.
Operating on the Seebeck Effect, thermocouples produce voltage proportional to temperature changes and metal properties. These insulated wire assemblies serve as critical safety and monitoring tools for industrial processes and equipment.
How Thermocouples Work
Two dissimilar wires form a junction where one wire (hot/measuring junction) measures temperature, while the other connects to a reference cold junction at known temperature. The thermocouple calculates unknown temperatures by comparing voltage at the hot junction with the reference temperature.
Product Images
Type S Thermocouple Cable product photo
Manufacturing Excellence
LEADKIN maintains advanced production lines and equipment, ensuring all products comply with international quality standards and meet diverse market requirements worldwide.
Thermocouple cable manufacturing equipment Quality control and testing processes
Packaging & Quality Assurance
Each coil cable includes heat shrink tubing and plastic film for high insulated resistance. All shipments include marking notes, pass cards, and comprehensive test reports.
Thermocouple cable packaging with quality documentation
Ordering Process
  1. Request accurate quotation
  2. Confirm pricing, trade terms, lead time, and payment terms
  3. Receive Proforma Invoice with official seal
  4. Arrange deposit payment and provide bank slip
  5. Production updates with photos showing your products
  6. Final production photos before shipment
  7. Complete balance payment and receive tracking information
  8. Receive goods and confirm satisfaction
  9. Provide feedback on quality, service, and market performance

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.

Manufacturer, Importer, Exporter, Seller
  • Annual Revenue: 5000000-10000000
  • Employees: 100~200
  • Year Established: 2009