Price | $1000-$100000/set |
MOQ | 1set(MOQ) |
Delivery Time | 15Days OR To be negotiated |
Brand | BAIKONG |
Place of Origin | Sichuan,China |
Certification | IEC,GB |
Model Number | 630A Outdoor Isolator High Pressure |
Packaging Details | Standard wooden boxes for outer packing/To be negotiated |
Payment Terms | L/C, Western Union, T/T |
Supply Ability | 300 sets/sets per week |
Earthquake Intensity Does Not Exceed | 8 Degrees | Place of Origin | Sichuan,China |
Size | As Picture | Packaging Details | Standard wooden boxes for outer packing/To be negotiated |
Product Name | 630A Outdoor Isolator High Pressure | Color | As Picture |
Wind Speed Does Not Exceed | l00Pa | Model Number | 630A Outdoor Isolator High Pressure |
Supply Ability | 300 sets/sets per week | Certification | IEC,GB |
Ambient Temperature | -30°C-+40°C, Alpine region-40% | Rated Voltage | 10KV |
Brand Name | BAIKONG | Payment Terms | L/C, Western Union, T/T |
Series | High Voltage Isolating Switch | Price | $1000-$100000/set |
Delivery Time | 15Days OR To be negotiated | Minimum Order Quantity | 1set(MOQ) |
Rated Current | 630A | Altitude | 1000m |
630a
New
Ceramicsoutdoor
Isolation
On
The
Column
High-Pressure
Isolation
Switch
Use
outdoor
unipolar
disconnectors
(hereinafter
referred
to
as
switches)
are
suitable
for
12
kV
high-voltage
transmission
and
distribution
lines,
used
to
cut
off
and
close
single-phase
or
three-phase
circuits
without
voltage.
The
switch
is
for
single-phase
use
of
a
three-phase
line
system.
Its
structure
is
simple,
economical,
and
easy
to
use.
Outdoor
high
voltage
switchgear
is
a
single
phase
AC
50Hz
high
voltage
switchgear
for
power
on
or
isolation
at
12kV
in
a
power
system
rated
at
voltage
without
load.
Operating
Environment
12KV
Model | rated voltage (KV) | rated current (A) | drop-out current (A) |
impulse
voltage (BIL) |
Working frequency pressure resistance |
creep
distance (mm) |
weight (kg) |
outline
dimension (cm) |
GW9-10W/400 | 12 | 200 | 6300 | 100 | 42 | 350 | 3.8 | 42X35X11 |
GW9-10W/400 | 12 | 200 | 8000 | 110 | 42 | 350 | 3.8 |
10KV
Model | Rated Voltage (Kv) | Rated Current (a) | 4s Thermal Stable Current | Dynamic Current | Impulse Withstand Voltage | Working Frequency Pressure Resistance | ||
Relatively | Between The Broken Mouth | Relatively | Between The Broken Mouth | |||||
HGW9-10W/400A | 10 | 400 | 12500 | 31500 | 75 | 85 | 38 | 42 |
HGW9-10W/630A | 10 | 630 | 12500 | 31500 | 75 | 85 | 38 | 42 |
HTDW2
Model | Rated Voltage (Kv) | Rated Current (a) | 4s Thermal Stable Current | Dynamic Current | Impulse Withstand Voltage | Working Frequency Pressure Resistance | ||
Relatively | Between The Broken Mouth | Relatively | Between The Broken Mouth | |||||
GTDW2 | 0.5 | 800 | 1250 | 3150 | 4 | 5 | 2 | 3 |
GTDW2 | 0.5 | 1000 | 1250 | 3150 | 4 | 5 | 2 | 3 |
GWR1
Type | 120A | 150A | 220A | 300A | 360A | 470A | 600A |
GWR1 | 0.15 | 0.20 | 0.30 | 0.50 | 0.60 | 0.50 | 0.90 |
GWR1 | 80 | 100 | 150 | 180-2 | 250 | 315-320 | 400 |
The
rated
current
of
the
switch
is
200,
400,
630,
800,
1000
amps,
they
are
all
composed
of
the
base,
the
post
insulator,
the
conductive
part
and
the
mechanism
part.
A
knife-type
structure
is
used
to
open
and
close
the
circuit
to
cut
off
and
close
the
line.
Each
phase
knife
is
composed
of
two
conductive
blades.
Compression
springs
are
installed
on
both
sides
of
the
blade.
The
height
of
the
spring
can
be
adjusted
to
obtain
the
contact
pressure
required
by
the
switch
knife.
When
the
switch
opens
and
closes,
the
hook
rod
operation
mechanism
can
be
used
to
perform
the
closing
movement.
The
knife
has
a
self-locking
device.
The
appearance
of
the
switch
is
shown
in
the
figure.
Second,
the
use
of
environmental
conditions
and
main
technical
parameters
1.
Use
environmental
conditions
(1)
The
altitude
does
not
exceed
2000
meters;
(2)
Ambient
temperature:
the
highest
is
not
higher
than
+
40
℃;
the
lowest
is
not
lower
than
-30
℃;
(3)
Outdoor
wind
speed
does
not
exceed
35
meters
/
second;
(4)
The
earthquake
intensity
does
not
exceed
8;
(5)
The
installation
site
should
be
free
of
gas,
steam,
chemical
precipitation,
salt
spray,
dust
and
dirt,
and
other
explosive
and
aggressive
media
that
seriously
affect
the
insulation
and
conductivity
of
the
switch.
3.
Installation,
use
and
adjustment
1.
Work
before
installation
(1)
Eliminate
the
dust
and
dirt
on
the
other
parts,
and
carefully
wipe
the
surface
of
the
insulated
porcelain
bottle;
(2)
Apply
a
layer
of
industrial
petroleum
jelly
to
the
rotating
parts
and
contact
points;
(3)
Check
the
contact
surface
and
adjust
the
width
of
the
compression
spring
so
that
the
contact
pressure
meets
the
following
table:
(4)
This
switch
is
only
suitable
for
hoisting
use
as
shown
in
Figure
4,
it
is
generally
used
in
conjunction
with
the
transformer
on
the
line;
(5)
The
rated
current
of
this
switch
is
generally
only
two
mounting
holes
in
200-400A,
630-1000A
uses
three
mounting
holes;
(6)
The
installation
method
and
installation
dimensions
are
shown
in
the
figure;
2.
Check
the
following
parts
of
the
switch
regularly
every
year
(1)
Remove
dust,
especially
conductive
parts,
contact
surfaces
and
insulating
porcelain
bottle
surface,
etc
.;
(2)
Check
whether
the
other
parts
are
damaged,
pay
special
attention
to
check
whether
the
insulating
porcelain
bottle
is
damaged
or
broken;
(3)
Check
whether
the
contact
surface
of
the
conductive
part
is
good;