                                        | Price | $12000 >=1 Set | 
| MOQ | 1 set | 
| Delivery Time | 35 work days | 
| Brand | Envsin | 
| Place of Origin | Guangdong | 
| Certification | ISO CE | 
| Model Number | EQF | 
| Payment Terms | L/C, D/A, T/T, D/P, Western Union | 
| Supply Ability | 20 sets per month | 
| Place of Origin | Guangdong | Warranty | 1 year | 
| Model Number | EQF | Supply Ability | 20 sets per month | 
| Certification | ISO CE | Brand Name | Envsin | 
| Payment Terms | L/C, D/A, T/T, D/P, Western Union | Gas concentration | 5ppm ~30ppm | 
| Wind speed | ≤ 1.7 m/s | Price | $12000 >=1 Set | 
| Delivery Time | 35 work days | Minimum Order Quantity | 1 set | 
| Gas | H2S,NO2,Cl2,SO2 | Power | AC380V 50Hz/60Hz 3/N/P | 
NO2 Cl2 SO2 H2S Gas Corrosion Test Chamber 25ppm
Our service:
 
         
          | 
              
              
              
              Main
              Technical
              Parameters
              (Model:EQF)
             | ||
| 
              
              Temperature  test
             | 
              
              
              Temperature
              range: 20℃~+45℃
             | 
              
              
              Remark:
             
              
              1.
              Test
              in
              accordance
              with
              IEC60068
             
              
              under
              empty
              chamber
              condition
              (except
              indicated).
             
              
              2.
              The
              test
              data
              of
              the chamber
              are
              
              under
              
              the
              
              conditions
              
              that
              
              the
              
              water temperature
              is
              
              
              less
              
              than
              
              28,
              the
              
              water
              
              pressure
              is
              between 0.3MPa
              and 0.6MPa,
              and
              the water
              pressure between
              inlet
              and
              outlet
              is
              more
              than
              0.2MPa.
             | 
| Temperature uniformity : ≤2.0℃ | ||
| Temperature deviation: ≤±2.0℃ | ||
| Temperature fluctuation: ≤ ±0.5℃ | ||
| Temperature change rate: ≥ 1℃/min | ||
| 
              
              Temp
              and
              humidity test
             | Temperature range: 20℃~50℃ Humidity range: 50%RH~85%RH | |
| Humidity uniformity: ±5.0% RH | ||
| Humidity deviation: +2.0% ~ 3%RH( >75%RH)±5%RH( ≤ 75%RH) | ||
| Gas concentration | The deviation of gas concentration in the test chamber shall be less than 10% of the set concentration | |
| The empty chamber operation is compliant with the IEC60068-2-60 | ||
| Gas concentration measurement | calculate the volume ratio and then through the mass flowmeter measurement | |
| On load capacity | 
              
              
               500W,The
              temperature
              can
              be
              stable,
              the
              chamber
              body
              is
              not
              deformed
             | |
| 
              
              Noise
             | Working noise ≤ 70dB ( measured at 1 meter away from the test chamber) | |
| Gas flowmeter | H2S,CI2,SO2,NO2 | |
| 
              
              Standard
             | IEC60068-2-1:2007 Test A: Low temperature test method | |
| 
              
              
              
               IEC60068-2-2:2007 Test
              B:
              High
              temperature
              test
              method
             | ||
| 
 
              
              
              
               IEC60068-2-78:2007 Test
              Cab:
              Constant
              humidity
              and
              
              Temperature test
             | ||
       
    
  