China Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue for sale
China Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue for sale
  1. China Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue for sale
  2. China Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue for sale

Concrete Hooked End Metal Glued Steel Fiber Resistance To Cracking Impact Fatigue

Price Negotiable
MOQ 1T
Delivery Time 10days
Brand Yusen
Place of Origin China
Certification ISO , CE
Model Number YS-65/35BG
Packaging Details 1.1*1.1*1.1m pallet
Payment Terms L/C, T/T, , Western Union, MoneyGram
Supply Ability 2000T/m

Product Details

Product Specification

Place of Origin China Shape Hooked and deformed
Packaging Details 1.1*1.1*1.1m pallet Material Steel Wire
Standard ISO8001 Model Number YS-65/35BG
Dosage 15kgs Supply Ability 2000T/m
Certification ISO , CE Tensile strength 1165Mpa
Brand Name Yusen Payment Terms L/C, T/T, , Western Union, MoneyGram
Delivery Time 10days Product name Concrete Glued Hooked End Metal Steel Fiber
Minimum Order Quantity 1T Secondart Not
Application Bulk heavy warehouse

Product Description

Concrete Glued Hooked End Metal Steel Fiber

 

Glued Steel Fiber Introduction

 

Steel fiber concrete flooring can provide superior resistance to minimize cracks in hardened concrete, as well as maximum resistance to withstand heavy loads, either dynamic or static. If you decide to use steel fiber concrete flooring, you can select to use a ‘joint-less floor’. Joint-less floors are floors that have minimal joints, providing spaces without joints as large as 40 or 50-meter span wide.
 

Steel fiber dosage will vary greatly upon the project intended use, and the types of mesh being replaced. Common dosages are in the range between 20-30kg/m3 to 40-50kg/m3 for joint-less floors

Typically the fibers are added at the batch plant, just after all concrete aggregates are being mixed. Some people would request to have the fiber added at the job site, but then the QA/QC should have more control on how much fiber is added. The steel fiber manufacturer can provide guidance on how to mix and the amount needed to obtain the desired results. Be aware that if you add too much fiber, it might show up at the surface when finishing the concrete so be cautious about the amounts being mixed.

 

Glued Steel Fiber Specs

 

Glued
Steel Fiber
Model Diameter (mm) Length (mm) Aspect ratio (mm) Tensile strength (MPa)
YS-60/60BG 1 60 60 ≥1100
YS-50/50BG 1 50 50 ≥1100
YS-65/60BG 0.9 60 65 ≥1100
YS-55/50BG 0.9 50 55 ≥1100
YS-80/60BG 0.75 60 80 ≥1100
YS-45/35BG 0.75 35 45 ≥1100
YS-55/30BG 0.55 30 55 ≥1100
YS-60/30BG 0.5 30 60 ≥1100
YS-50/25BG 0.5 25 50 ≥1100
YS-60/25BG 0.4 25 60 ≥1100

 

 

Advance of End Hooked Glued Steel Fiber

 

  • Improved flexural properties
  • Reduced absorption of water, chemicals, etc.
  • Can be used on fast track schedule
  • Easier positioning of joints
  • Reduced site labor for managing steel reinforcement
  • Reduced project costs
  • Increased impact and abrasion resistance
  • Even distribution of fibers throughout the concrete

 

Technical and engineering support

  • We support you at everytime
  • Setting up your project specification
  • Recommend the most appropriate fiber type to dosage rates to guarantee performance and comply with the specifications.

 

Package and Delivery:

 

 

 

 

Hebei Yusen Metal Wire Mesh Co.,Ltd.

Manufacturer
  • Annual Revenue: 500-1000
  • Employees: 50~80
  • Year Established: 2005