Price | Negotiable |
MOQ | 1000 |
Delivery Time | 7 Days |
Brand | WWHS |
Place of Origin | CN |
Certification | CE |
Model Number | D-D |
Packaging Details | Colorful Paper Box |
Payment Terms | T/T |
Supply Ability | 50000 Kits per Week |
Place of Origin | CN | Keywords | High Stability, High Accuracy |
Packaging Details | Colorful Paper Box | Product Name | D-Dimer Rapid Quantitative Test Kit |
Reaction Time | 10 min. | Quantity | 25T |
Throughput | 6000 Tests/Day | Model Number | D-D |
Supply Ability | 50000 Kits per Week | Feature | High Sensitivity |
Certification | CE | Brand Name | WWHS |
Payment Terms | T/T | Storage | 4-30℃ |
Price | Negotiable | Delivery Time | 7 Days |
Sample Type | WB / Plasma | Minimum Order Quantity | 1000 |
Manufacturer | WWHS Biotech INC | Application In | WWHS NIR-1000 Dry Fluoroimmunoassay Analyser |
【Product name】
D-Dimer Rapid Quantitative Test(Fluorescence immunoassay)
【Package specification】
20 Tests/box
【Intended use】
This kit is used for quantitative determination of D-dimer in human whole blood and plasma.
【Inspection principle】
The principle of immunofluorescence chromatography was applied to the kit. The D-dimer antigen in the sample was first bound with the conjugated compound of fluorescent labeled D-dimer monoclonal antibody, then moved and combined with another D-dimer monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.
【Main components】
Name | Quantity | Component |
Test card | 25 | It is composed of fluorescent pad (coated with fluorescent labeled D-dimer monoclonal mouse antibody), nitrocellulose membrane (coated with D-dimer monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing |
Sample buffer | 25(300μL/tube) | Phosphate buffer |
ID card | 1 | Record the standard curve information of this kit |
The components in different batches of kits cannot be used interchangeably.
【Storage conditions and validity】
The test card should be stored at 4℃~30℃, dry, dark and no freezing. It should be stored in sealed aluminum foil bag and valid for 12 months. The test card should be returned to room temperature (15℃~30℃) before opening. It should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.
The production date, batch number and expiration date are shown in the outer package of the product.
【Applicable instruments】
NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.
【Sample requirements】
【Procedure】
【Reference interval】
By measuring 268 healthy people aged between 19 and 79, statistical analysis shows that the reference interval is less than 500 ng/ml. According to the characteristics of the local population, the reference intervals of the laboratories were established.
【Interpretation of results】
【Limitations of methods】
【Performance】
1. Analysis sensitivity
No more than 40ng/ml.
2. Accuracy
The relative deviation from the target value is within ±15%.
3. Precision
The within and between assay coefficient of variations are within 15%.
4. Linear range
Within the linear range (40 ~ 10000ng/ml), the linear correlation coefficient R≥0.990.
【Note】
1. This kit is only used for in vitro diagnosis.
2. The test card and sample diluent are disposable and cannot be reused.
3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃~30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.
4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.
5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.
Assay list | ||||||
Cardiac | ||||||
cat#. | Product Item | Specimen | Reaction Time | Measure Range | Clinical Range | Intended Use |
1 | cTnI | WB/Serum/Plasma | 12min. | 0.1-40ng/ml | <0.3ng/ml | several heart diseases including myocardial infarction and heart failure. |
2 | Myo | WB/Serum/Plasma | 12min. | 5-400ng/ml | <58ng/ml | acute myocardial infarction (AMI) in early stage. |
3 | CK-MB | WB/Serum/Plasma | 12min. | 1-200ng/ml | <5ng/ml | acute myocardial infarction (AMI) in early stage. |
4 | NT-proBNP | WB/Serum/Plasma | 10min. | 20-35000pg/ml |
Under
75:0~347pg/mL, Over 75:0~449pg/mL |
heart failure . |
5 | D-Dimer | WB/Plasma | 10min. | 40-10000ng/ml | <500ng/ml | disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc. |
6 | cTnI+Myo+CKMB | WB/Serum/Plasma | 12min. | same with single item | same with single item | Triple marker of myocardial infarction. |
7 | ST2 | WB/Serum/Plasma | 10min. | 10-400ng/ml | <35ng/ml | heart failure . |
8 | Lp-PLA2 | WB/Serum/Plasma | 10min. | 10-900ng/ml | <175ng/ml | Risk evaluation of ACS and atherosclerotic ischemic stroke patients. |
9 | S100-β | WB/Serum/Plasma | 10min. | 0.05-10ng/ml | <0.2ng/ml | Cerebral infarction, cerebral injury. |
Application In
NIR-1000 Dry Fluoroimmunoassay Analyser
Wide-Range Diagnostics, It can be used in following areas:
1) Department of thoracic Surgery
2) Clinical Laboratory
3) Department of Emergency
4) First Aid Community Hospital
5) Department of Respiration
6) CCU/ICU
7) Department of cardiology
8) Department of Geriatrics
About
Payment:
1. We accept the T/T, 30% as deposit, and the rest should be payed before shipment.
2.
L/C
is
welcome
when
the
account
is
too
large.
3.
Our
price
is
often
FOB
shenzhen,
or
FOB
shenzhen
airport,
and
EXW,
CIF,
and
so
on.
4. We normally ship by Shenzhen.All products shipped with careful packaging to protect and ensure safety of contents during shipment.
5. We do not responsible for any custom taxation if applicable in some country.
6. We do everything to provide you the most reliable way of shipping service. Yet sometimes international delivery is highly depended on the local customs and post service.
Advantage:
1. Advanced Quality: We have strict quality control system and enjoy good reputation in the market.
2. Sincerly Service: We treat clients as friend and aims at building long term business relatiionship.
FAQ:
Q.
How
is
your
company's
product
after-sales
service
system?
A.
The
product
warranty
period
is
12
months,
we
can
provide
lifetime
maintenance.
We
have
professional
pre-sales
and
after-sales
teams
that
can
respond
to
you
within
24
hours
to
resolve
technical
issues.
We
provide
one-to-one
after-sales
service.
Q:
Can
you
customize
it?
A:
Yes,
we
accept
customization
according
to
customer's
specific
requirements.
Q.
How
long
is
your
lead
time?
If
I
want
to
customize
instruments,
how
long
will
it
take?
A.
When
order
quantity
is
1-10
units,
we
have
ready
stock
goods,
we
can
ship
out
within
3-5
working
days
after
receipt
of
deposit;
products
required
new
production
of
common
materials,
usually
the
lead
time
is
about
10-15
days;
products
requiring
new
production
of
special
and
rare
materials,
usually
the
lead
time
is
about
20-30
days.
Most Of FIA Rapid Test Cassette Assay Such As Cardiac and Inflammation Items Are Available For 5-10 days Prompt Shipment.
Q.
What
payment
method
do
you
accept?
A.
Our
company
accept
payment
method
of
T/T
(bank
transfer),
Western
Union,
PayPal
and
so
on.
Q.
What
package
do
you
use
for
your
products?
What
shipping
method
do
you
use?
A.1.
Our
company
use
standard
exporting
carton
for
packing.
2.
We
ship
via
express
courier
(door
to
door
service),
by
air,
and
by
sea
according
to
customers'
requirements.
For more questions, please feel free to send inquiries to us.