Price | Negotiable |
MOQ | 1000 |
Delivery Time | 7 Days |
Brand | WWHS |
Place of Origin | CN |
Certification | ISO13485, CE |
Model Number | PCT |
Packaging Details | Colorful Paper Box |
Payment Terms | L/C, T/T |
Supply Ability | 50000 Kits per Week |
Place of Origin | CN | Warranty | 12 Months |
Packaging Details | Colorful Paper Box | Product Name | PCT Rapid Test Kit |
Model Number | PCT | Health Detecting | Vitro Diagnosis |
Supply Ability | 50000 Kits per Week | Feature | High Sensitivity, High Accuracy |
Certification | ISO13485, CE | Brand Name | WWHS |
Payment Terms | L/C, T/T | Applicable Instruments | NIR-1000 Dry Fluorescent Immunoassay Analyzer |
Reactivity | Human | Format | Cassette |
Advantage | Accurate | Price | Negotiable |
Delivery Time | 7 Days | Formal Name | Procalcitonin |
Minimum Order Quantity | 1000 | Sample Buffer | 25 Vials |
[Product Name]
Procalcitonin (PCT) Rapid Quantitative Test (Fluorescence immunoassay)
[Packing Specification]
25 Tests/kit
[Intended Use]
The product is used to determine the content of procalcitonin (PCT) in whole blood, plasma and serum of human body and is mainly used clinically for auxiliary diagnosis of bacterial infectious diseases.
[Test Principle]
The kit uses immunochromatographic assay. First, PCT antigen in the sample combines with the fluorescently-labeled PCT monoclonal antibody conjugate. Then, it continues to move and combines with another PCT monoclonal antibody fixed on the nitrocellulose membrane to form double-antibody sandwich immune complex in the position of the nitrocellulose membrane test line and analyze and obtain quantitative test result using NIR-1000 dry fluoroimmunoassay analyser.
[Main Ingredients]
Name | Loading capacity | Ingredient |
Test card | 25 | The product consists of fluorescent mat (coated with fluorescently-labeled PCT monoclonal murine antibody), nitrocellulose membrane (coated with PCT monoclonal murine antibody and goat anti mouse IgG antibody), absorbent paper and bottom lining. |
Sample diluent | 25 | Phosphate buffer |
ID card | 1 | Record standard curve information of this batch of reagents |
Ingredients of kits of different batch numbers cannot be exchanged.
[Storage Conditions and Validity]
The product should be stored at 4℃-30℃ in a dry and dark place, sealed using aluminum foil bag and must not be frozen. The storage life is 12 months. The test card should be unpacked at room temprature (15℃-30℃) and should be used in 15min after unpacked at a temperature of (15-30)℃ and relative humidity of 20%-90%.
See outer packing for production date, batch number and expiry date.
[Applicable Instrument]
NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.
[Sample Requirements]
[Test Method]
【Reference Interval】
Determine 254 healthy people aged 18-68 and carry out statistical analysis. Result shows that the upper limit of the reference value is 0.5ng/mL at the 95th percentile, so the reference interval is less than 0.5ng/mL.
The laboratory should establish a reference range according to characteristics of local people.
[Interpretation of Test Results]
1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.
2. For samples whose PCT concentration is lower than 0.2ng/mL and higher than 100ng/mL, test result is “<0.2ng/mL” and “>100ng/mL” respectively.
[Limitation of Test Method]
1. The kit can be used to test whole blood, plasma and serum specimens of human body only.
2. Due to limitations of serological methods for antigen and antibody response, the test result cannot be used as the only basis for clinical diagnosis and should be evaluated together with all existing clinical and experimental data.
5. When human anti mouse concentration of samples is less than 50ng/mL, HAMA effect will not be observed.
6. When RF concentration of samples is less than 2000 IU/mL, the test result will not be affected.
[Product Performance Indicators]
No more than 0.2ng/mL
The relative deviation to the target value is limited to ±15%.
Within-run precision CV≤15%; between-run relative limit R≤15%.
Within the specified linearity range (0.2-100) ng/mL, linearly dependent coefficient r≥0.990.
【Precautions】
Interpretation of results
1.
This
reagent
is
only
used
for
auxiliary
detection.
If
the
test
results
are
abnormal,
it
should
be
reviewed
in
time
and
judged
in
combination
with
clinical
symptoms.
2.
For
samples
with
AFP
concentration
lower
than
2.5ng/ml
and
higher
than
200ng/ml,
the
detection
results
are
reported
as
"<
2.5ng/ml"
and
">
200ng
/ml",
respectively.
Limitations
of
methods
1.
This
kit
is
only
used
to
detect
human
plasma/whole
blood
samples
2.
Due
to
the
limitations
of
immunoassay
methods
of
antigen
and
antibody
reaction,
the
results
cannot
be
used
as
the
only
basis
for
clinical
diagnosis,
but
should
be
evaluated
with
all
the
existing
clinical
and
experimental
data.
3.
The
content
of
triglyceride
in
the
sample
shall
not
exceed
15mg/ml,
the
content
of
hemoglobin
shall
not
exceed
5mg/ml,
and
the
content
of
bilirubin
shall
not
exceed
0.5mg/ml,
and
the
relative
deviation
of
the
test
results
shall
not
exceed
±15%.
4.
When
the
concentration
of
AFP
in
the
sample
is
less
than
20000ng/ml,
there
is
no
hook
effect.
5.
HAMA
effect
was
not
produced
when
the
concentration
of
human
anti
rat
in
the
sample
was
less
than
50ng/ml.
6.
When
RF
concentration
in
the
sample
is
less
than
2000IU/ml,
the
relative
deviation
of
the
test
results
is
within
±15%.
Applicable
Instrument
WWHS NIR-1000 dry fluoroimmunoassay analyser
WWHS Advantage
1. Advanced Quality: We have strict quality control system and enjoy good reputation in the market.
2. Sincerly Service: We treat clients as friend and aims at building long term business relatiionship.
3. Affordable Price: We always ensure high price performance to benefit our customers.
4. Timely Delivery: Your order shall be shipped once finished