Price | Negotiable |
MOQ | 1000PCS |
Delivery Time | 7-10 workdays |
Brand | FUSEI |
Place of Origin | DONGGUAN,GUANGDONG,CHINA |
Certification | CQC/CCC/UL |
Model Number | Y 3A 250V |
Packaging Details | Bulk,1000pcs per bag |
Payment Terms | T/T, Western Union |
Supply Ability | 50000pcs per day |
Place of Origin | DONGGUAN,GUANGDONG,CHINA | Certifications | UL,CCC,CQC |
Packaging Details | Bulk,1000pcs per bag | Limit temperature | 180 deg |
Model Number | Y 3A 250V | Housing | Insulated plastic |
Supply Ability | 50000pcs per day | Alloy | Low melting point alloy |
Certification | CQC/CCC/UL | Name | Temperature Thermal Cutoff Fuse |
Rated Voltage | 250V | Limited time overload current | 45A |
Brand Name | FUSEI | Payment Terms | T/T, Western Union |
Breaking current | 4.5A | Price | Negotiable |
Delivery Time | 7-10 workdays | Minimum Order Quantity | 1000PCS |
Lead | Tinned plated copper | Rated Current | 3A |
Rated operating temperature Tf | 75~150 deg | Coating | Special resin |
Metal Ceramic Type 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse for Fan Motor
1 Product description Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
A thermal fuse or thermal cutoff is a safety device which open circuits against overheat. It detects the heat caused by the over-current due to short circuit or component breakdown. Thermal fuses do not reset themselves when the temperature drops like a circuit breaker would.
Y series thermal fuse introduction: thermal fuse is composed of fuse wire and insulated shell, mainly used in electrical and electronic product equipment and its parts. It is mostly used in indoor electrical equipment, mainly to protect electrical equipment from overheating under abnormal conditions. Once the fuse is to be reset, only the temperature fuse of the same type and specification can be used.
2 Working principle Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
When the temperature of the equipment rises abnormally, the thermal fuse is induced to heat, and when the temperature reaches the set temperature of the alloy, the low melting point is melted, and the surface tension of the molten alloy increases under the action of the special resin, causing the alloy to shrink in a spherical shape. On the lead wire, the circuit is completely cut off.
3 Anatomy Diagram Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
a | b | c | d | e |
Insulation Case | Low melting point alloy |
Special resin |
Seal resin |
Tinned plated copper |
4 Product installation guidelines Of The The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
* Keep a distance of 3mm from the fuse body when bending the wire.
* When welding or soldering exceeds the rated temperature of the fuse, the longer the welding distance and the shorter the welding time, the less damage to the fuse.
* Be careful of the current flowing in the insurance body.
* Do not use liquids or toxic gases such as sulfuric acid and nitric oxide.
* Do not connect the heater and the fuse directly.
5 Dimension Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse (mm)
A | B | C | D | E※ |
6.1±0.2 | 6.8±0.2 | 2.6±0.2 | 0.5±0.02 | 70±2 |
5.1±0.2 | 5.4±0.2 | 2.4±0.2 | 0.5±0.02 | 50±2 |
Length can be customized on request |
6 Electrical Performances Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
P/N |
Rated operating temperature Tf(℃) |
Actual operating temperature (℃) |
Hold temperature Tc(℃) |
Limit temperature Tm(℃) |
额定电压Rated Voltage (V) |
电流Rated Current (A) |
Breaking current (A) |
Limited time overload current (A) |
Y01 | 75 | 72±1 | 55 | 130 | 250 | 3 | 4.5 | 45 |
Y02 | 76 | 73±1 | 55 | 130 | 250 | 3 | 4.5 | 45 |
Y03 | 80 | 75±2 | 58 | 130 | 250 | 3 | 4.5 | 45 |
Y05 | 85 | 80±2 | 62 | 130 | 250 | 3 | 4.5 | 45 |
Y06 | 90 | 85±2 | 65 | 130 | 250 | 3 | 4.5 | 45 |
Y07 | 95 | 90±1 | 68 | 130 | 250 | 3 | 4.5 | 45 |
Y08 | 98 | 96±1 | 70 | 130 | 250 | 3 | 4.5 | 45 |
Y09 | 100 | 97±1 | 72 | 130 | 250 | 3 | 4.5 | 45 |
Y10 | 102 | 98±1 | 72 | 150 | 250 | 3 | 4.5 | 45 |
Y11 | 103 | 99±2 | 73 | 150 | 250 | 3 | 4.5 | 45 |
Y12 | 105 | 100±2 | 75 | 150 | 250 | 3 | 4.5 | 45 |
Y18 | 110 | 105±1 | 80 | 150 | 250 | 3 | 4.5 | 45 |
Y20 | 115 | 111±2 | 87 | 150 | 250 | 3 | 4.5 | 45 |
Y28 | 120 | 115±1 | 90 | 150 | 250 | 3 | 4.5 | 45 |
Y30 | 125 | 121±2 | 95 | 150 | 250 | 3 | 4.5 | 45 |
Y32 | 126 | 121±2 | 95 | 150 | 250 | 3 | 4.5 | 45 |
Y33 | 127 | 122±2 | 96 | 150 | 250 | 3 | 4.5 | 45 |
Y35 | 130 | 126±1 | 102 | 150 | 250 | 3 | 4.5 | 45 |
Y36 | 133 | 130±1 | 103 | 150 | 250 | 3 | 4.5 | 45 |
Y38 | 135 | 130±1 | 105 | 150 | 250 | 3 | 4.5 | 45 |
Y39 | 136 | 131±1 | 105 | 150 | 250 | 3 | 4.5 | 45 |
Y46 | 140 | 136±1 | 110 | 160 | 250 | 3 | 4.5 | 45 |
Y48 | 145 | 140±1 | 114 | 180 | 250 | 3 | 4.5 | 45 |
Y50 | 150 | 146±1 | 120 | 180 | 250 | 3 | 4.5 | 45 |
7 Company Introduction Of The The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
*
Our
company
is
located
in
Shilong
Town,
Dongguan
City,
Guangdong
Province.
It
is
a
high-tech
enterprise
specializing
in
the
production
of
thermal
fuses.
*
Since
its
establishment,
the
company
has
been
committed
to
the
development,
production
and
application
of
thermal
fuses.
The
products
have
passed
CCC,
VDE,
TUV,
UL,
SGS
certification,
and
the
quality
system
has
passed
ISO9000
certification.
The
company
has
independent
development
capabilities
and
can
develop
various
products
required
by
customers
in
accordance
with
customer
requirements.
At
present,
the
company's
research
and
development
capabilities,
production
control,
product
quality,
and
quality
assurance
capabilities
have
reached
the
advanced
level
in
the
same
industry.
*
The
RH
temperature
fuse
produced
by
our
company
is
suitable
for
power
transformers,
power
switches,
sockets,
rectifiers,
fitness
massagers,
electric
blankets,
energy-saving
lamps,
communication
tools
and
other
household
appliances.
It
is
an
indispensable
safety
for
protecting
electrical
products
and
preventing
electrical
fires.
Accessories.
To
*
The
company
adheres
to
the
principle
of
"doing
the
job
well
the
first
time",
with
fast
delivery
as
the
main
line,
and
reasonable
price
as
the
competitiveness,
to
provide
manufacturers
with
satisfactory
products
and
services.
8 Quality Assurance Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
9 More Products Of The 1A 2A 3A 5A 10A 15A 16A 250V Temperature Thermal Cutoff Fuse
10 What are the characteristics of the Thermal Fuse?
Thermal
fuse
has
the
characteristics
of
accurate
melting
temperature,
high
withstand
voltage,
small
size
and
low
cost.
The
thermal
fuse
shell
is
marked
with
the
rated
temperature
value
and
the
rated
current
value,
it
is
not
difficult
to
identify,
and
it
is
very
convenient
to
use.
It
can
be
widely
used
in
electrical
equipment,
electric
heating
equipment
and
practical
electrical
appliances
for
overheating
protection.
Thermal
fuse
mainly
has
the
following
parameters:
①
Rated
temperature:
Sometimes
called
the
operating
temperature
or
fusing
temperature,
it
refers
to
the
temperature
at
which
the
temperature
rises
to
the
fusing
temperature
at
a
rate
of
1°C
per
minute
under
no-load
conditions.
②
Fusing
accuracy:
refers
to
the
difference
between
the
actual
fusing
temperature
of
the
thermal
fuse
and
the
rated
temperature.
③
Rated
current
and
rated
voltage:
Generally,
the
nominal
current
and
voltage
of
thermal
fuse
have
a
certain
margin,
usually
5A
and
250V.
Thermal
fuse
is
a
one-time-use
protection
element.
Its
use
affects
not
only
depends
on
the
performance
of
the
element
itself
but
more
importantly,
on
how
to
select
and
install
the
thermal
fuse
correctly.
The
thermal
fuse
is
generally
connected
in
series
in
the
circuit
when
it
is
used.
Therefore,
when
choosing
a
thermal
fuse,
its
rated
current
must
be
greater
than
the
current
used
in
the
circuit.
Never
allow
the
current
through
the
thermal
fuse
to
exceed
the
specified
rated
current.
Before
selecting
the
rated
temperature
of
the
thermal
fuse,
you
must
understand
and
measure
the
temperature
difference
between
the
temperature
to
be
protected
and
the
location
where
the
planting
fuse
is
installed.
In
addition,
the
length
of
the
fusing
time
and
the
availability
of
ventilation
are
also
closely
related
to
the
selection
of
the
rated
temperature
of
the
thermal
fuse.