| Price | Negotiable | 
| MOQ | 1 Set | 
| Delivery Time | 5-8 work days | 
| Brand | CLX | 
| Place of Origin | Guangdong,China | 
| Model Number | CLX-DJ02 | 
| Packaging Details | Pe bag + outer box, or customized requirements | 
| Payment Terms | T/T | 
| Supply Ability | 50 set/week | 
| Place of Origin | Guangdong,China | Keywords | Fiber optic ceramic ferrule dispensing | 
| Warranty | 1 years | Use | FTTH | 
| Size | 235mmX225mmX63mm | Packaging Details | Pe bag + outer box, or customized requirements | 
| Material | Steel and aluminum | Model Number | CLX-DJ02 | 
| Supply Ability | 50 set/week | Weight | 33 KG | 
| Brand Name | CLX | Payment Terms | T/T | 
| Price | Negotiable | Delivery Time | 5-8 work days | 
| Product name | fiber optic glue injection machine | Minimum Order Quantity | 1 Set | 
| Adhesive | early plastic, glue, glue advance off switch delay | 
Automatic Fiber Optic Epoxy Injecting Machine For Fiber Optic Ferrules
High Precision Efficiency Fiber Optic Equipment Automatic Fiber Optic Epoxy Injection Machine
Model:CLX-DJ02
Place of Origin:ShenZhen,China
Description
CLX-DJ02 semi-automatic dispenser is controlled by a film tap switch.Can adjust manual, semi-automatic state, the use of digital timing controller accurate to seconds, the correct control of flow, will not waste liquid material, it is easy to change each infusion volume and infusion time.It can solve many problems in stock development. It is simple to use and easy to operate. Equipped with vacuum suction function, it is not easy to fatigue, no waste, and has a wide range of use.
  
  1.
  Uniquely
  designed
  tooling
  fixture,
  finishing
  the
  material
  in
  an
  instant
  2.
  The
  XYZ
  axis
  adopts
  Japanese
  dispensing
  technology,
  and
  the
  dual
  guide
  rails
  support
  in
  parallel,
  with
  high
  transmission
  accuracy
  and
  stable
  performance.
  3.The
  main
  steps
  of
  the
  movement
  adopt
  Japanese
  motor
  +
  American
  synchronous
  belt,
  Taiwan
  linear
  guide,
  high
  accuracy
  and
  long
  life.
  4.
  Mainly
  applicable
  to
  most
  of
  the
  core
  insert
  injection
  of
  SC
  /
  LC
  /
  FC.
  The
  injection
  speed
  is
  fast
  (3600PCS
  /
  H),
  the
  consistency
  of
  the
  injection
  amount
  is
  strong,
  the
  glue
  amount
  is
  stable,
  saving
  manpower
  and
  material
  resources.
Specifications
| Dispensing travel X/Y/Z(mm) | 200/200/50mm | 
| Maximum Load | Y-AXIS / Z-AXIS: 8kg / 3kg | 
| Travel speed X&Y / Z (mm/sec) | 0.1-800 / 350mm/sec | 
| Repeatability | +/- 0.02 mm/200 | 
| Program recording mode | 100 groups, 4000 points per group (U disk COPY) | 
| Teaching handle | LCD (320×240mm),English Interface | 
| I/O Signal I/O | 8 Inputs / 8 Outputs | 
| Input power supply | AC110/220V (internal switch conversion) 350W | 
| Transmission method | Timing belt + precision linear guide | 
| Dimensions (WxDxH mm) | 413×439×535mm | 
| Body weight (kg) | 33KG | 
Packaging & Shipping
  
  
  Professional
  packaging:
  1pc
  with
  poly
  bag.
  
  wooden
  case
  and
  canton
  box
  are
  available.
  
  make
  sure
  the
  machine
  safe.
  
  Shipping
  :7
  working
  days
  after
  order
  confirmed
  
  
Matching fixture
  
Acrylic sheet 1 Pieces
  
Ceramic ferrule discharge 3 Pieces
  
Cover 1 Pieces
Attention and maintenance:
1, Air pressure cant be more than 7bar(10psi), working air pressure cant be more than 5.5bar (78psi), if the working air pressurer is more than 4 bar, pls use the original parts from the manufacter.
2, The liquid material must be stired evenly before putting to the cyliner needle. It will be better if the liquid material can be stored at the stable temperature of 5 degree centigrade to make sure there is no big change in the density of the liquid material. If the density of the liquid is so high, ( it means the liquid is so viscous, it may be hard to spit out). If the liquid need to be diluted, pls compliant to the instruction of the liquid material manufacture.
3, Dont sharply increase the Vacuum, otherwise, the liquid will be pulled in the catheter by the vacuum. The qty of the vacuum pumpback rely on the air pressure level, working cycle, qty of the liquid to spit. If the qty of the vacuum is too much, the piston will be overset, disturbing the normal work.
4, Avoid to overset the liquid cylinder, otherwise, the liquid will flow to the air cylinder to destroy the internal aprt.
5, Pls clear the stuff left in the cylinder needel when needed. Otherwise the stuff will become hard, then disturbing the vacuum pumpback and stop the cylinder needle.
6, After using the machine, the cylinder needle need to be cleaned every time, otherwise, it is difficult to unload the needle when the liquid becomes hard. Normally, it is easy to remove the liquid from the inside of the cylinder needle, just dipping the parts in the hand water for 5~10minutes, all the part will be cleaned.
7, Pls disposal the used needle and cylinder needle at appropriate place to avoide some i nappropriate liquid pollution
  
FAQ
1.Are you a factory or a trader?
......we are factory.
2.What is your MOQ?
......MOQ 1 piece.
3.Do you provide sample services?
......Yes, we will provide samples(Samples at prices announced by chuanglixun).
4.How will you ship to me?
....... We will spend 4 to 6 days via DHL or FedEx. Properly extended based on order quantity
5.How do we pay
......Book in advance or multiple payment methods such as T / T and T / L.
6.How long is your product warranty?
......The warranty period is 1 year (the warranty period will provide free repairs, except for consumables). After the warranty period, accessories will continue to be provided and will be charged at cost.
7.Do you provide customized services?
......Yes, we provide customized services, According to customer requirements and description