| Name | DC air pump | Bearing | sleeve bearing |
| Brand Name | Zhaoli | Payment Terms | L/C, T/T, Western Union |
| Packing | Customized packing | Delivery Time | 25-45 days |
| Rated voltage | 6.0VDC | Minimum Order Quantity | 2000 |
| Pump type | diaphragm air pump | Application | portable nebulizer/ blood pressure |
Blood Pressure Use DC Air Pump And Electromagnetic Valve 6.0VDC 300mmHg
Diaphragm Pump Specification:
Electric characteristics
| Rated voltage | 6.0VDC |
| Operating voltage | 4.0 - 7.2 VDC |
| Rated current | The highest current is less than 380mA while pressurizing with DC6.0V from 0 to 300mmHg. |
| Inflation time | It takes Less than 10 seconds to pressurize with DC6.0V from 0 to 300 mmHg in a 500cc tank. |
| Leakage | Pressurizing from 0 till 300±30mmHg in a 500CC tank, then holding for 30 seconds. After that, measuring the dropped pressure value, which shall be less than 2.0mmHg/min. |
| Max pressure | The maximum pressure value shall be more than 400 mmHg while pressurizing with DC 6.0 V in a 500CC tank from 0 till dead-head pressure value. |
| Restart voltage | Fill pressure until 200mmHg pause,and then add DC 3.0V voltage pump should restart. |
| Dielectric strength | 600VAC/1S leakage current <=5mA |
| Temperature rise | <60K |
Electromagnetic Valve Specification:
| Rated voltage | 6.0VDC |
| Operating voltage | 4.0 - 7.2 VDC |
| Rated current | 60mA +/-10% |
| Rated power | 0.36W |
| Range of operation pressure | Max 330mmHg |
| Insulation class | A |
| Used fluid | Air |
| Temperature rise | <40K |
| Leakage | Pressurizing from 0 till 300mmHg in a 300CC tank .then holding for 30 seconds. After than, measuring the dropped pressure value, which shall be less than 3mmHg/min |
| Exhaust speed | With 500CC volume, it takes less than 4.0seconds to exhaust the pressure from300mmHg to 15mmHg |
| Insulation resistance | The insulation resistor is 50MΩ Min at DC500V between Coil and non-charge Metal. |
| Dielectric strength | It has to test between coil and outer mental parts at applying AC 500V for 1minute,and if no damage and abnormality occurs, then test at AC 600V for 1second. |
Drawing:

Application: Blood pressure, portable nebulizer, Inhaler, Atomizer