                                        | Price | USD | 
| MOQ | 1EA | 
| Delivery Time | 3-5 DAYS | 
| Brand | B&R | 
| Place of Origin | Austria | 
| Certification | COC | 
| Model Number | 8BVP0880HC00.004-1 | 
| Packaging Details | Original | 
| Payment Terms | T/T | 
| Supply Ability | 10EA | 
| Input voltage | 25 VDC ±1.6% | Place of Origin | Austria | 
| Warranty | 1 Year | Packaging Details | Original | 
| Dimensions | 213.5*317*212mm | Model Number | 8BVP0880HC00.004-1 | 
| Supply Ability | 10EA | Certification | COC | 
| Weight | Approx. 7.9 kg | Brand Name | B&R | 
| Payment Terms | T/T | Product Brand | B&R | 
| Price | USD | Delivery Time | 3-5 DAYS | 
| Product Type | Power Supply | Output voltage | 24 V +5.8% / -0.1% | 
| Minimum Order Quantity | 1EA | Product Model | 8BVP0880HC00.004-1 | 
 
8BVP0880HC00.004-1
ACOPOSmulti power supply module, 88 A, AS, cold plate or pass-through mounting
| B&R ID code | 0xA6A1 | 
| Cooling and mounting type | Cold plate or pass-through mounting | 
| Slots for plug-in modules | 2 | 
| Certifications | |
| CE | Yes | 
| UL | cULus
              E225616 Power conversion equipment | 
| EAC | Yes | 
| KC | Yes | 
| Network configurations | TT, TN-S, TN-C-S | 
| Mains input voltage | 3x 220 to 3x 480 VAC ±10% | 
| Frequency | 50 / 60 Hz ±4% | 
| Installed load | Max. 62 kW | 
| Inrush current at 400 VAC | Max. 133 A | 
| Switch-on interval | >300 s | 
| Max. DC bus capacitance depending on mains voltage | |
| 230 VAC | 34.8 mF | 
| 400 VAC | 11.5 mF | 
| 480 VAC | 8 mF | 
| Nominal switching frequency | 5 kHz | 
| Possible switching frequencies | 5 / 10 kHz | 
| Integrated line filter per EN 61800-3, category C3 | No | 
| Integrated regeneration choke | No | 
| Regenerative | Yes | 
| Power factor correction (PFC) | Yes | 
| Variant | |
| L1, L2, L3, PE | M8 threaded bolts | 
| Shield connection | Yes | 
| Connection cross section range | |
| Flexible and fine-stranded wires | --- | 
| Terminal cable cross section dimension of shield connection | 32 to 50 mm | 
| Voltage | |
| Nominal | 750 VDC | 
| Continuous power (supply and regeneration) | 60 kW | 
| Reduction of continuous power depending on mains input voltage | |
| Mains input voltage <3x 400 VAC | 150 W/V * (400 V - Mains input voltage) | 
| Reduction of continuous power depending on DC bus voltage (UDC) | |
| UDC <750 VDC | 0.08 kW/V | 
| Reduction of continuous power depending on switching frequency and mounting type | |
| Switching frequency 5 kHz | |
| Cold plate mounting | 1.3 kW/K (starting at 58°C) | 
| Pass-through mounting | In preparation | 
| Switching frequency 10 kHz | |
| Cold plate mounting | 0.95 kW/K (starting at 27°C) | 
| Pass-through mounting | In preparation | 
| Reduction of continuous power depending on installation elevation | |
| Starting at 500 m above sea level | 6 kW per 1000 m | 
| Peak power (supply and regeneration) | 120 kW | 
| Power dissipation depending on switching frequency | |
| Switching frequency 5 kHz | [0.065*P²+11.4*P+90] W | 
| Switching frequency 10 kHz | [0.22*P²+16.1*P+185] W | 
| DC bus capacitance | 1650 µF | 
| Protective measures | |
| Overload protection | Yes | 
| Short-circuit and ground fault protection | No | 
| Variant | ACOPOSmulti backplane | 
| Input voltage | 25 VDC ±1.6% | 
| Input capacitance | 4.7 µF | 
| Max. power consumption | 27 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF... | 
| Variant | ACOPOSmulti backplane | 
| Quantity | 2 | 
| Output voltage | |
| DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC / 315) | 
| DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% | 
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset | 
| Output voltage | 24 V +5.8% / -0.1% | 
| Continuous current | 4.2 A | 
| Max. overcurrent limiting | 10 A | 
| Protective measures | |
| Overload protection | No | 
| Short-circuit proof | Yes | 
| Open-circuit monitoring | No | 
| Undervoltage monitoring | No | 
| Quantity | 2 | 
| Circuit | Sink | 
| Electrical isolation | |
| Input - Power supply module | Yes | 
| Input - Input | Yes | 
| Input voltage | |
| Nominal | 24 VDC | 
| Maximum | 30 VDC | 
| Switching threshold | |
| Low | <5 V | 
| High | >15 V | 
| Input current at nominal voltage | Approx. 10 mA | 
| Switching delay | |
| Rising edge | 52 μs ±0.5 μs (digitally filtered) | 
| Falling edge | 53 μs ±0.5 μs (digitally filtered) | 
| Modulation compared to ground potential | Max. ±38 V | 
| Discharge capacitance | 0.9 µF | 
| Permissible mounting orientations | |
| Hanging vertically | Yes | 
| Horizontal, face up | Yes | 
| Standing horizontally | No | 
| Installation elevation above sea level | |
| Nominal | 0 to 500 m | 
| Maximum | 4000 m | 
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) | 
| Overvoltage category per EN 61800-5-1 | III | 
| Degree of protection per EN 60529 | IP20 | 
| Temperature | |
| Operation | |
| Nominal | 5 to 40°C | 
| Maximum | 55°C | 
| Storage | -25 to 55°C | 
| Transport | -25 to 70°C | 
| Relative humidity | |
| Operation | 5 to 85% | 
| Storage | 5 to 95% | 
| Transport | Max. 95% at 40°C | 
| Dimensions | |
| Width | 213.5 mm | 
| Height | 317 mm | 
| Depth | |
| Cold plate | 212 mm | 
| Pass-through mounting | 209 mm | 
| Weight | Approx. 7.9 kg | 
| Module width | 4 | 