Price | Negotiable |
MOQ | 1000PCS |
Delivery Time | 5-7 Days |
Brand | Tian Rui |
Place of Origin | China |
Certification | UL+cUL TUV CCC |
Model Number | L1 Series |
Packaging Details | 1000PCS/Bag |
Payment Terms | D/P, T/T,Paypal, Western Union |
Supply Ability | 1000000PCS/Month |
Reset Time | Within 60 seconds | Place of Origin | China |
Packaging Details | 1000PCS/Bag | Model Number | L1 Series |
Supply Ability | 1000000PCS/Month | Method of Operation | R Type and J TYPE |
Certification | UL+cUL TUV CCC | Weight | Approx 25.0g (0.9 oz.) |
Rated Voltage | AC 125/250V DC 50V | Brand Name | Tian Rui |
Payment Terms | D/P, T/T,Paypal, Western Union | Reset Type | Auto Reset, Automatic Reset |
Price | Negotiable | Delivery Time | 5-7 Days |
Minimum Order Quantity | 1000PCS | Interrupt Capacity | 125VacX1000A 250VacX200A |
1 ,500Vac 1 minute | 1 ,500Vac 1 minute | Rated Current | 3A-60A |
Insulation Resistance | >500 MΩ | Resettable Overload Capacity | Ten Times Rated Current |
Motor Automatic Auto Reset L1 Circuit Breaker 3A 5A 6A 10A 16A 20A 25A 30A 35A 40A 50A 60A 125V 250V AC
L1 Series "SERIES TRIP", "PUSH TO RESET" Single Pole circuit breakers represent our largest selling product family. Bases on a proven "SNAP ACTING" bimetallic thermal seneing elemant system. L 1 Series circuit breakers sease Overload conditions and interupt the flow of Current. The resettable actuator mechenism then remains disengaged until manually reset.
L1 Series offers amperage ratings from 3A to 60A, and is suitable for a diversity of applications, our products are carefully calibrated and tested to ensure reliable performance under a variety of operating assignments and conditions.
Rated Voltage | AC 125/250V DC 50V |
Rated Current | 3~60A |
Interrupt Capacity | 125VacX1 000A 250VacX200A |
Insulation Resistance | >500 MΩ |
Resettable Overload Capacity | Ten Times Rated Current |
Dielectric Strength | 1 ,500Vac 1 minute |
Weight | Approx 25.0g (0.9 oz.) |
Voltage Drop | Less than 0.25V |
Reset 1 rime | Within 60 seconds |
Method of Operation | R Type and J TYPE |
Mechanical / Environmental Data
Operating
Temperture
Range:
-10°C
to
60°C
Termination:
250"
(6.35mm)
quick
conects
or
solder
terminals
Mounting:
Various
options.
See
Ordering
lnfomation
and
drawings
Temperature
Rise
at
Terminal
Block:
Less
than
65°C
at
100%
of
rated
current
applied
continuously
at
25°C
Contact
Endurance:
125Vac
X
150%
of
rated
current
>500
Cycles
Typical
Resistance
VS.
Current
Rating
@
+25°C
|
|||
Current
Rating in
Amps
|
TvpicalResistance in Ohms | Current Rating in Amps | Typical Resistance in Ohms |
5.0 | 0.052 | 15.0 | 0.017 |
6.0 | 0.042 | 20.0 | 0.012 |
7.0 | 0.036 | 25.0 | 0.010 |
8.0 | 0.031 | 30.0 | 0.008 |
10.0 | 0.025 | 35.0 | 0.007 |
12.0 | 0.021 | 40.0 | 0.006 |
Capacity
Correction
Factors
For Ambient
Temperatures
|
||||||||||
Temperature
|
||||||||||
Current Rating Amps | °F | +14 | +32 | +50 | +68 | +77 | +86 | +104 | +122 | +140 |
°C |
-10 |
+0 | +10 | +20 | +25 | +30 | +40 | +50 | +60 | |
3
to
8A
|
.70 | .80 | .92 | .98 | 1.00 | 1.10 | 1.25 | 1.61 | 2.00 | |
9
to
40A
|
.74 | .78 | .83 | .90 | 1.00 | 1.05 | 1.15 | 1.31 | 1.55 |
The unit is calibrated for ambient temperature of +25°C. To determine the rated current for a lower or higher ambient Temperature, use a correction factor as above.
100% of rated current | Hold, No-Trip |
135% of rated current |
Trip
in
1
Hour
|
200% of rated current |
Within
40
Seconds
|
300% of rated current |
Within
10
Seconds
|
Approval | File No. | Rated Current Range | Rated Voltage | Standard |
UL+cUL | E478741 | 3~50A | 125/250VAC | UL1077 |
TUV | 50046704 | 3~50A | 125/250VAC | EN60934 |
CCC | 2014010307693248 | 3~50A | 125/250VAC | GB17701 |
UL :+cUL | E482018 | 3~50A | 125/250VAC | UL244A |
Working Principle of L1 Circuit Breaker
An overload protector (circuit breaker) protects the compressor by sensing temperature and current. It is composed of a set of normally closed contacts and bimetallic elements. The overcurrent overload protector is mounted on the outside of the compressor, in direct contact with the compressor casing and in series with the compressor windings. If the compressor cannot be started for some reason, the overloaded locked-rotor current will cause the bimetal element to heat up and bend rapidly, causing the contact to quickly trip, cutting off the current flowing through the compressor, thereby protecting the compressor. Similarly, if the motor of the compressor is abnormally heated and the temperature of the windings of the compressor is too high, the protector will heat up and trip, thereby protecting the compressor. As long as the cause of the failure is not ruled out, the compressor will start and stop with the action of the bimetallic element over and over again in the case of overcurrent and overload.
Application Range of Overcurrent Overload Protector
Products are widely used in small household appliances, generators, air compressors, automobiles, electric vehicles, power tools, extension cords, transformers, large complete sets of equipment, plugs and sockets, etc.
Overload Overload Protector Inspection Method
Check with an ohmmeter
1.
If
the
overcurrent
overload
protector
is
open,
wait
until
it
cools
down
to
room
temperature
(closed)
to
continue
the
measurement.
2.
Although
it
is
possible
to
continuously
observe
the
operation
of
the
overload
protector,
it
is
difficult
to
confirm
whether
the
part
is
working
according
to
the
specifications.
3.
If
you
cannot
confirm
whether
there
is
any
problem
with
the
overcurrent
and
overload
protector,
please
replace
the
parts
with
the
same
specifications
and
parameters.
Warning:
The
overcurrent
and
overload
protector
cannot
be
bypassed,
even
for
temporary
measurement,
it
must
be
replaced
with
a
substitute
that
meets
the
regulations,
and
the
overcurrent
and
overload
protector
cannot
be
cancelled
casually.