| Price | $1000.00/Sets 1-9 Sets |
| MOQ | 10 sets |
| Delivery Time | 7~15 working days |
| Brand | ZGD |
| Place of Origin | Guangdong, China |
| Certification | CE |
| Model Number | ZGD3115 |
| Packaging Details | Wooden Box |
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability | 1000 Set/Sets per Month |
| Place of Origin | Guangdong, China | Phase | 3 Phase In 1 Phase Out |
| Packaging Details | Wooden Box | Port | Shenzhen or Guangzhou |
| Model Number | ZGD3115 | Supply Ability | 1000 Set/Sets per Month |
| Battery Type | Sealed Lead Acid Battery | Certification | CE |
| Weight | 125KG | Brand Name | ZGD |
| Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Price | $1000.00/Sets 1-9 Sets |
| Delivery Time | 7~15 working days | Product name | Online UPS Systems |
| Capacity | 15KVA | Minimum Order Quantity | 10 sets |
| Wave Form | Pure Sine Wave | Application | INSTRUMENTATION |
| Certificate | CE/ROSH/GS/TUV/MSDS | Display | LED+LCD (7inch Color Touch Screen) |
★
Three
phase
380VAC
in,
one
phase
220VAC
out
★
True
on-line
double
conversion
design
to
provide
the
best
power
quality
★
Advanced
micro-processor
control
technology
to
enhance
the
availability
and
reliability
of
the
system
★
SPWM
technology,
IGBT
power
modules
and
the
output
isolation
transformers,
to
ensure
the
output
from
the
power
grid
fluctuations
and
noise
interference;
★
Advanced
technology
of
Lock-in
synchronization
and
electronic
static
bypass-switch,
to
ensure
the
continuity
of
load
power
supply
★
Super
phase-failure
work
ability
ensures
the
system’s
stable
power
supply
under
the
circumstances
of
very
bad
power
grid
supply
★
Wide
Input
voltage
windows
to
reduce
the
use
frequency
of
the
battery,
effectively
extending
the
service
life
of
the
battery
★
Wide
Input
frequency
windows
for
Generator
compatible
★
ABM
Smart
battery
management
technology
to
effectively
protect
the
battery,
extending
the
battery
life;
★
Parallelable
current-equalizer
charger,
current
imblance
≤3%,
to
the
maximum
to
satisfy
the
configuration
requirements
of
the
system
★
Perfect
protection
design
to
greatly
ensure
the
stability
and
reliability
of
the
system
operation
★
Super
cold-start
capability,
cold
started
under
full-loaded
to
meet
the
user’s
urgent
requirements
| Model | ZGD3115 | |||||||||
| Capacity | 15KVA | |||||||||
| AC Input | ||||||||||
| Voltage | 3-phase 380VAC±20% | |||||||||
| Frequency | 50(60) Hz ±5% | |||||||||
| Max current | 16A | |||||||||
| AC Output | ||||||||||
| Voltage | Single phase 220VAC | |||||||||
| Frequency | 50(60) Hz | |||||||||
| Voltage range | ±1% | |||||||||
| Frequency range | ±0.5% (when mains supply failure) | |||||||||
| Wave form | SPWM pure sine wave | |||||||||
| Power factor | 0.8(lag) | |||||||||
| THD | <3%(linear load) | |||||||||
| Transient response | Voltage change ≤4%(100% load into or out ) | |||||||||
| Battery | ||||||||||
| Voltage | 192VDC | |||||||||
| Type | Sealed lead acid, maintenance free | |||||||||
| Charge time | 90% capacity after 8-10 hours | |||||||||
| Protection Settings inside | ||||||||||
| Battery | Automatically switch off UPS while battery low-voltage; | |||||||||
| Restarting while mains supply resume; Small circuit breaker protection | ||||||||||
| Over-load | Automatically switch to bypass in 60 seconds when overload 120%-150% ; Automatically resume when load become normal | |||||||||
| Over-temperature | Automatically switch to bypass when temperature >85℃ inside UPS | |||||||||
| Output short circuit | Current limit, turn off automatically, Small circuit breaker protection | |||||||||
| UPS abnormal | Automatically switch to bypass | |||||||||
| Clutter filter | 10~100KHz at 40dB; 100KHz~100MHz at 70dB | |||||||||
| Control panel | ||||||||||
| LCD panel | Working mode, I/ O voltage, I/ O frequency, Battery voltage, Output power percentage, Inverter temperature | |||||||||
| UPS status indicator light | Mains mode;battery mode;inverter mode;bypass mode;UPS abnormal | |||||||||
| Communication | RS232 interface; external SNMP adaptor (optional) | |||||||||
| Environment | ||||||||||
| Temperature | 0~40℃ | |||||||||
| Humidity | 20~90% non-condensing | |||||||||
| Altitude | <1000m(rated power reduces 5% for each additional altitude 500m) | |||||||||
| Noise | <58dB (1m) | |||||||||
| Appearance | ||||||||||
| Method of connecting wire | Terminal blocks | |||||||||