China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale
China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale
  1. China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale
  2. China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale
  3. China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale
  4. China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale
  5. China Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5 for sale

Ventilator Sterilizable Exhalation Expiration Valve Disinfected Assembly 115-021461-00 Mindray SV300 SV600 SV800 E3 E5

Price Negotiable
MOQ 1
Delivery Time 3-5 working days
Brand Mindray
Model Number 115-021461-00
Payment Terms T/T, Western Union,PayPal

Product Details

Product Specification

Warranty 90days Steam autoclave 134ºC
Company tenet Original assembled real product, quality guarantee, deliver on time, preference price Minimum purchasing quantity 1unit
Model Number 115-021461-00 After-sale Service In the warranty period and non-human damage can go to the sale free of charge for new
Product Status In Good working condition. Steam Time 10 to 20 minutes
Brand Name Mindray Payment Terms T/T, Western Union,PayPal
Type SV300 SV600 SV800 E3 E5 Delivery Time 3-5 working days
Product name Mindray Sterilizable expiration valve assembly Part No. 115-021461-00
Minimum Order Quantity 1 Applications Scenes ICU, emergency, Patient Monitor, Ventilator, ICU Room and operating room
Stock Status In stock Key Word Expiration Valve

Product Description

 

Mindray SV300 SV600 SV800 E3 E5 ventilator sterilizable exhalation Expiration Valve Disinfected assembly EXP valve PN 115-021461-00

 

 

 

 

► Brief Introduction

The Sterilizable expiration valve assembly is mainly responsible for functions such as pressure control, pressure monitoring and flow monitoring of the patient’s expiratory PHiliphhilipase. Thus, the various components of the expiration module must be cleaned and disinfected before being reused.

The patient’s exhaled warm and moist gas is condensed when it flows through the expiratory hose. The condensed water remains on the hose wall and finally enters the water trap. Whenthe patient’s exhaled gas arrives at the expiration valve, condensed water may appear at the expiration valve (including the expiratory flow sensor), compromising the measurement accuracy of expiratory flow sensor.

Check the Sterilizable expiration valve assembly for water build-up when abnormal flow waveform or unstable tidal volume fluctuation is detected. If there is water build-up inside the expiration valve, clear it before use.

Check the expiratory water trap for water during the use of the ventilator. If there is water build-up, empty it promptly. Water condensation in the expiration valve can be reduced by using a bacteria filter between the expiratory tube and expiration valve

 

 

Expiration Valve Assembly and Membrane

A: Expiration valve assembly

B: Expiration valve handwheel

C: Expiration valve membrane

D: Locked state of the expiration valve

E: Unlocked state of the expiration valve

 

 

 

► To disassemble:

  1. Rotate the expiration valve handwheel until the indicating arrow position. Then pull the expiration valve assembly out of the assembly horizontally.
  2. Remove the expiration valve membrane.

 

 

► To install:

  1. Install the expiration valve membrane onto the expiration valve assembly.
  2. Ensure that the indicating arrow position.

 

Methods for Cleaning and Disinfection

Parts Recommended frequency Interval Cleaning Disinfection
Expiration valve membrane (silicone) Each patient/weekly Immersion Immersion or Autoclaving
Expiration valve assembly (except membrane) Each patient/weekly Immersion Immersion or Autoclaving
  • Immersion: Flush with water first and then immerse it in alkalescent detergent (soapy water, etc., water temperature of 40ºC recommended) for approximately three minutes. Finally, clean with water and dry completely.
  • Autoclaving : Steam autoclave at 134ºC for 10 to 20 minutes (recommended time).

 

►Delivery Policy

We are shipped the goods worldwide as soon as payment is received, insured and tracked as standard using trusted couriers, such as DHL, FedEx, UPS, etc,.

Getting your equipment to you swiftly and safely is of utmost importance to us. Costs will depend on your location, how quickly you’d like your package, and what you have ordered.

If your order is taking longer than expected or you want to find out when it will arrive, please contact us.

 

 

Please kindly contact us, if you are interested in Mindray SV300 SV600 SV800 E3 E5 ventilator sterilizable exhalation Expiration Valve Disinfected assembly EXP valve PN 115-021461-00, Thank you!

 

China World Technology Medical Equipment Service Group

Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
  • Employees: 20~50
  • Year Established: 2015